background image

12

Troubleshooting

Symptom

Possible Cause

Solution

Power indicator LED 

does not light; tool is 

non-responsive .

1) Battery pack not charged .

2) AC adapter is connected 

to tool . 

1) Connect AC adapter to tool 

and charge battery pack . Refer 

to 

Setup 

for instructions .

2) Remove AC adapter . 

Fault LED lights during 

charging .

1) Problem with battery pack .

2) Internal failure .

1) Disconnect AC adapter from 

tool and wait one hour for 

battery pack to cool . Do not 

use tool or attempt to charge 

battery pack during this time . 

After one hour, reconnect AC 

adapter to tool. If red LED 

(fault) illuminates again, 

replace battery pack .

    Refer to 

Replacement Parts

 

section of this manual .

2) If battery pack is not the 

problem, discontinue using tool 

and return it for service . 

CauTiOn: This tool should 

be serviced by TiF only. Failure 

to do so may impair the 

intrinsic safety of the device.

Tool does not seem 

operable; does not alarm 

in the presence of leaks .

1) Sensor failed .

2) Internal failure .

1) Verify unit on known 

combustible gas leak source . If 

no response, replace sensor . 

Refer to 

Maintenance

 for 

instructions .

2) If replacing sensor does not 

solve problem, immediately 

discontinue using tool and 

return it for service .

CauTiOn: This tool should 

be serviced by TiF only. Failure 

to do so may impair the 

intrinsic safety of the device.

Summary of Contents for TIF TIF8800X

Page 1: ...TIF8800X Combustible Gas Detector Owner s Manual Manual del propietario Manuel de l utilisateur an spx brand...

Page 2: ...n an area known to be non hazardous The process of charging or replacing the battery pack could cause a spark and in an environment containing combustible gas could lead to an explosion Reinstall the...

Page 3: ...s 3 Setup 4 Install the Battery Pack 4 Charge the Battery Pack 5 Operating Instructions 6 Instrument Status Indicators 7 Maintenance 8 General Care 8 Battery Pack 8 Sensor 9 Specifications 10 Replacem...

Page 4: ...tion where a combustible gas vapor or residue needs to be found Some applications are Gas lines and pipes Fuel leaks Liquid or gas fired heating systems Propane filling stations warning The TIF8800X i...

Page 5: ...Instrument status indicators five LEDs 3 Probe tip and sensor 4 NiMh battery pack behind cover 5 Charger input jack 6 Leak intensity indicators six LEDs 7 Sensitivity control Parts and Controls 1 7 6...

Page 6: ...amber See Figure 1 Setup 4 4 Reinstall the battery cover and screw 5 Reinstall the rubber boot caution To prevent personal injury always reinstall the rubber boot Failure to do so may impair the intri...

Page 7: ...e is illuminated Once charging is complete the green LED READY will also illuminate Notes Leaving the AC adapter connected to the tool after charging will not damage the tool However the tool will not...

Page 8: ...leak When a detectable compound enters the tip the tick rate speeds up Along with the increased tick rate the leak intensity LEDs illuminate from left to right The larger the concentration the more L...

Page 9: ...a battery charge is needed The battery pack must be fully recharged before the tool is used again Charge yellow This LED illuminates during the recharge process Ready green This LED illuminates when t...

Page 10: ...apter into an appropriate wall outlet and connect the charger jack to the tool During the charge cycle the yellow LED charge is illuminated Once charging is complete the green LED READY will also illu...

Page 11: ...l the sensor straight out of the sensor socket 2 Align the pins in the new sensor with the receptacles in the sensor socket and push the sensor into place 3 Test the tool in the presence of a known le...

Page 12: ...cles Warm up Period Approximately 30 seconds Duty Cycle Continuous no limitation Response Time Instantaneous Sensitivity Variable as low as 1 ppm gasoline vapor Operating Environment 32 F to 125 F 0 C...

Page 13: ...review the Troubleshooting section of this manual to determine if the problem can be solved If the tool still fails to work correctly contact the company at 800 327 5060 for more information Repaired...

Page 14: ...If red LED fault illuminates again replace battery pack Refer to Replacement Parts section of this manual 2 If battery pack is not the problem discontinue using tool and return it for service caution...

Page 15: ...To condition battery pack charge it fully then operate tool as normal until the low battery LED illuminates Repeat this procedure a minimum of 3 to 5 times Tool does not operate and battery pack char...

Page 16: ...0 Rev B August 11 2010 655 Eisenhower Drive Owatonna MN 55060 0995 USA Toll free 800 327 5060 llamada gratuita 800 327 5060 num ro gratuit 800 327 5060 Fax 866 259 1241 tel copieur 866 259 1241 www ti...

Reviews: