8
kvs values for SD M U 4
valves in ( m 3 / h )
SD M U 45,
SD M U 46
SD M U 45,
SD M U 46
D N
25
40
38
38
50
70
70
65
80
100
Tube
1T
1,5T
38
38
2T
70
70
2,5T
3T
4T
8. Technical Data
Product-wetted parts:
316 L, 1.4404
Other parts:
1.4301
Seals:
Standard:
EPDM
Option:
HNBR
Membrane:
TFM / EPDM
Actuators:
1.4301
Max. operating temperature:
140 °C EPDM, HNBR
Sterilization temperature:
up to 150 °C EPDM
(short-term)
140 °C HNBR
Air connection (for hose):
6 x 1 mm
Max. pneumatic air pressure:
8 bar
Min. pneumatic air pressure:
6 bar
(Use dry and clean pneumatic air, only.)
Closing times for double seal valves SDMU4
The opening and closing times can be fixed by adjustment of the
throttling screw at the solenoid valve.
Double Seal Change-Over Valve
with Diaphragm
Delta SDMU 4