Paraflow Plate Heat Exchanger
Instruction Manual
Section 5.0
Issue 5
Page 24 of 36
June 13, 2008
4.
Starting with the top pair of tie bars, continue
tightening equally about 1/4” at time until the
platage dimension measures about 5% above the
final dimension.
5.
Install the remaining tie bars (if applicable) above
the top ports and below the bottom ports of the
frame. Starting with the top pair and working
down, tighten each pair 1/8” at a time. After each
tightening cycle of 1/8”, return to the top set of
bars and repeat the procedure.
NOTE:
On large heat exchangers using 2”, 42 mm or
48 mm diameter tie bars, it may only be possible
to achieve 1/16” movement during the final stages
of tightening.
6.
Tighten the exchanger to the maximum platage
dimension specified on the plate arrangement
drawing. The dimension must be the same at all
tie bars. See
Figure 24
NOTE:
Due to o-ring type gasket seal,
the final
closed dimension is determined by dimension
,
not tie bar torque.
Manufacturing tolerances of the plate may result in
the actual minimum platage dimension varying.
Refer to your plate arrangement drawing for actual
minimum and maximum dimensions.
7.
Pressure test the heat exchanger for leaks by
using
potable water
at the desired pressure but
do not exceed the pressure specified on the
drawing. The test may be done on each side
separately or on both sides at once. Make sure all
air is vented from the heat exchanger before
performing the pressure test.
8.
If leaks occur, the heat exchanger may be further
tightened and retested. It is suggested that this be
done in steps of approximately 0.001” per plate
until the leak stops or the minimum dimension
specified on your general arrangement drawing is
reached.
9.
If the leaks continue, mark them carefully and
open the exchanger in accordance with Paragraph
5.7. Inspect the area of the leaks closely for
damaged gaskets, plates, sealing surfaces or
debris. Replace all suspect plates or gaskets,
clean the sealing surface with a lint free cloth, and
repeat steps 1 through 7.
5.7
Opening Tie Bar Frames
Tie bar frames may be opened safely by following
steps 1 through 6 in Paragraph 5.6 in reverse order.
The tie bars must be loosened in the same sequence
and amount as described in each step.
WARNING:
Refer to your plate arrangement drawing
for the proper tightening plate dimension
.
WARNING:
Never open a Paraflow until the unit has
been cooled below 100
°
F (38
º
C).
Never open a Paraflow which is under
pressure from any source.
Never open a Paraflow with piping
connected to the follower or connector
grids.
Figure 24
Platage Dimension
Kemper County MM218132
Approved
Summary of Contents for S280 M-14
Page 3: ...Kemper County MM218132 Approved...
Page 10: ...Kemper County MM218132 Approved...
Page 11: ...Kemper County MM218132 Approved...
Page 12: ...Kemper County MM218132 Approved...
Page 13: ...Kemper County MM218132 Approved...
Page 14: ...Kemper County MM218132...
Page 15: ...Kemper County MM218132...
Page 16: ...Kemper County MM218132...
Page 17: ...Kemper County MM218132 Approved...
Page 18: ...Kemper County MM218132 Approved...
Page 19: ...Kemper County MM218132 Approved...
Page 20: ...Kemper County MM218132 Approved...
Page 21: ...Kemper County MM218132 Approved...
Page 22: ...Kemper County MM218132 Approved...
Page 23: ...Kemper County MM218132 Approved...
Page 24: ...Kemper County MM218132 Approved...
Page 25: ...Kemper County MM218132 Approved...
Page 26: ...Kemper County MM218132 Approved...
Page 27: ...Kemper County MM218132 Approved...
Page 28: ...Kemper County MM218132 Approved...
Page 29: ...Kemper County MM218132 Approved...
Page 30: ...Kemper County MM218132 Approved...
Page 31: ...Kemper County MM218132 Approved...
Page 32: ...Kemper County MM218132 Approved...
Page 33: ...Kemper County MM218132 Approved...
Page 34: ...Kemper County MM218132 Approved...
Page 35: ...Kemper County MM218132 Approved...
Page 36: ...Kemper County MM218132 Approved...
Page 37: ...Kemper County MM218132 Approved...
Page 38: ...Kemper County MM218132 Approved...
Page 39: ...Kemper County MM218132 Approved...
Page 40: ...Kemper County MM218132 Approved...
Page 41: ...Kemper County MM218132 Approved...
Page 42: ...Kemper County MM218132 Approved...
Page 43: ...Kemper County MM218132 Approved...
Page 44: ...Kemper County MM218132 Approved...
Page 45: ...Kemper County MM218132 Approved...
Page 46: ...Kemper County MM218132 Approved...
Page 47: ...Kemper County MM218132 Approved...
Page 48: ...Kemper County MM218132 Approved...
Page 49: ...Kemper County MM218132 Approved...
Page 50: ...Kemper County MM218132 Approved...
Page 51: ...Kemper County MM218132 Approved...
Page 52: ...Kemper County MM218132 Approved...
Page 53: ...Kemper County MM218132 Approved...
Page 54: ...Kemper County MM218132 Approved...