28
Problem solving
CRL/EN (1810) 2.2
Table 4: Possible causes of pump failures.
Possible causes
1
Pump or suction pipe is not sufficiently filled or de-aerated
2
Gas or air coming from the liquid
3
Air lock in the suction pipe
4
Air leak in the suction pipe
8
The manometric suction head is too high
9
Suction pipe or suction strainer is blocked
10
Insufficient immersion of foot valve or suction pipe during operation of the pump
11
NPSH available too low
12
Speed too high
13
Speed too low
14
Wrong sense of rotation
15
Pump does not operate at the right duty point
16
Liquid density differs from the calculated liquid density
17
Liquid viscosity differs from the calculated liquid viscosity
18
Pump operates when the liquid flow is too low
19
Wrong pump selection
20
Obstruction in impeller or pump casing
21
Obstruction in the piping
22
Wrong installation of the pump unit
23
Pump and motor not well aligned
24
Rotating part running out of true
25
Imbalance in rotating parts (for instance: impeller or coupling)
26
Pump shaft is running out of true
27
Bearings faulty or worn out
28
Casing wear ring faulty or worn out
29
Damaged impeller
37
Axial retaining of impeller or pump shaft is defective
38
The bearings have been mounted wrongly
39
Too much or too little bearing lubrication
40
Wrong or polluted lubricant
41
Impurities in the liquid get into the stuffing box packing
42
Too high axial force because of worn dorsal blades or excessive inlet pressure
Summary of Contents for Johnson Pump CombiProLine OH3
Page 2: ......
Page 4: ...2 EC EN 1712 6 0 ...
Page 6: ...4 INT EN 1512 1 2 ...
Page 10: ...8 CRL EN 1810 2 2 ...
Page 20: ...18 General CRL EN 1810 2 2 ...
Page 40: ...38 Dimensions CRL EN 1810 2 2 ...
Page 52: ...50 Parts CRL EN 1810 2 2 ...
Page 66: ...64 ORDFORM 1512 3 3 EN ...