SPX Cooling Technologies Marley Aquatower Brochure Download Page 9

9

/  Field Assembly  /

1.  Maximum m

3

/hr applies to both pump and gravity flow piping sys-

tems. The outlet piping on gravity flow systems must have sufficient 

vertical drop to overcome  all other head losses in the system.

2.  Bottom outlet is not available on Models 490A and 490B.

 

Field Assembly

If you choose to assemble your Aquatower at the job site, 

your Aquatower will be shipped unassembled with complete 
assembly instructions.

The following table shows the sizes and weights of the 

largest Aquatower components for each model. You can 
use this information to plan your rigging and transportation 
needs.

Unassembled tower shipment may add 3 to 5 weeks to 

normal lead times. Your Marley sales representative will be 
glad to help you plan for your unique needs.

Volumes  shown  are  maximums  for  the  flowrate  ranges  indicated.  

Actual volumes will usually be less. Contact your local Marley sales 

representative for more specific information.

Note:

 

For economical transportation, Aquatowers are normally 

packaged unassembled when shipped from the UK by sea or air 
freight.

Bottom Outlet Maximum m

3

/hr

Tower 

Model

Outlet Diameter

4"

6"

8"

10"

492A - 492B

27

51

51

na

493A - 493B

27

61

79

na

494a - 494B - 494C

32

70

79

142

495A - 495B

32

70

79

193

496A - 496B

32

70

79

193

Drain-Down Capacity

Tower Model

Range of Tower Design m

3

/hr

Maximum Drain-Down 

litres

490A
490B

3.4 - 5.9

106

6.2 - 11.6

114

11.8 - 19.3

125

19.5 - 34.7

136

492A
492B

4.77 - 12

185

12.6 - 209

204

21 - 34.3

227

34.5 - 47.9

246

493A
493B

7.5 - 18.8

291

19 - 32.7

318

32.9 - 54

356

54.2 - 74.5

382

494A 
494B 

494C

13.6 - 32

507

32.3 - 51.5

549

51.7 - 85.4

613

85.6 - 127.8

674

495A
495B

18.6 - 43.6

689

43.8 - 61.3

727

61.5 - 116.5

829

116.7 - 173.3

912

496A
496B

23.6 - 44.5

863

44.7 - 64.9

920

65.1 - 112.8

1026

113.1 - 218.7

1211

Component Sizes and Weights

Tower Model

Component

Size mm

Weight kg

490A
490B

Collection Basin End

305 x 330 x 914

7

Collection Basin Floor

76 x 762 x 813

11

Front Panel

51 x 914 x 112

10

Casing Panel

51 x 102 x 132

20

Distribution Basin

203 x 406 x 813

8

492A
492B

Collection Basin End

356 x 406 x 122

11

Collection Basin Floor

76 x 914 x 112

17

Front Panel

51 x 122 x 173

24

Casing Panel

51 x 660 x 1600

16

Distribution Basin

203 x 406 x 112

11

493A
493B

Collection Basin End

356 x 406 x 183

17

Collection Basin Floor

76 x 914 x 1727

26

Front Panel

51 x 940 x 183

16

Casing

51 x 660 x 1600

16

Distribution

203 x 406 x 173

17

494A 
494B 

494C

Collection Basin End

457 x 457 x 1829

22

Collection Basin Floor

102 x 864 x 1727

26

Front Panel

51 x 1117 x 1829

19

Casing Panel

51 x 1016 x 1930

29

Distribution Basin

203 x 711 x 1727

24

Optional Discharge Side

51 x 1041 x 1956

17

Optional Discharge Floor

229 x 1143 x 1727

21

495A
495B

Collection Basin End

457 x 457 x 2438

29

Collection Basin Floor

102 x 864 x 2338

34

Front Panel

51 x 1118 x 2438

26

Casing

51 x 1016 x 1930

29

Distribution Basin

203 x 711 x 2337

32

Optional Discharge Side

51 x 1041 x 1956

17

Optional Discharge Floor

229 x 1143 x 1600

19

496A
496B

Collection Basin End

457 x 457 x 3048

36

Collection Basin Floor

102 x 864 x 2946

43

Front Panel

51 x 1168 x 3048

33

Casing Panel

51 x 1016 x 2134

32

Distribution Basin

203 x 711 x 2946

40

Optional Discharge Side

51 x 1143 x 1956

17

Optional Discharge Floor

229 x 1143 x 1956

25

Summary of Contents for Marley Aquatower

Page 1: ...MarleyAquatower CoolingTower...

Page 2: ...e all year long Proven Corrosion Protection Thousands of users over more than 40 years confirm the value of heavy galvanizing And Marley s Z 600 is the most effective galvanizing used in the industry...

Page 3: ...r of local distributors can draw from that stock Contact your local distributor or Marley representative They ll be glad to help you choose the proper model for your needs They can also help you with...

Page 4: ...et Install the desired connection and seal the unused opening with the cover plate provided Pump suction should use side outlet See page 9 for size and flow capacities of bottom outlets 7 Overflow is...

Page 5: ...TION BASIN 16mm DIAMETER HOLES TOWER COLLECTION BASIN B NORMAL GAUGE MIN BEARING WIDTH AT EACH ANCHOR BOLT 51 SUPPORT BY OTHERS TOWER COLLECTION BASIN SUPPORTING STEEL PLAN OPTION ONE VIEW B SECTION A...

Page 6: ...irborne trash out of the collection basin and fill area Hot water distribution basin covers are provided as standard equipment to keep the distribution basin free from airborne debris and to reduce th...

Page 7: ...onsist of welded heavy gauge steel wire hoops and spokes hot dip galvanized after fabrication The galvanized steel belt guard encloses both belts and pulleys Guards are easily removed for servicing Co...

Page 8: ...temperature dictates 5 Contact your Marley sales representative for selections appropriate for other ambient conditions than those shown here Indoor Tank Method In this type of system water flows from...

Page 9: ...2 494A 494B 494C 13 6 32 507 32 3 51 5 549 51 7 85 4 613 85 6 127 8 674 495A 495B 18 6 43 6 689 43 8 61 3 727 61 5 116 5 829 116 7 173 3 912 496A 496B 23 6 44 5 863 44 7 64 9 920 65 1 112 8 1026 113 1...

Page 10: ...stainless steel structure Or you can choose a galvanized tower with a stainless steel cold water collection basin Your Marley sales representative can help you choose the amount of corrosion resistanc...

Page 11: ...housing with externally accessible remote oil reservoir for easy maintenance Fill Louvers and Drift Eliminator Fill shall be film type thermoformed PVC with louvers and drift eliminator formed as par...

Page 12: ...BANK WORCESTER WR3 8AB UNITED KINGDOM 44 0 1905 720 200 info uk spx com spxcooling com In the interest of technological progress all products are subject to design and or material change without noti...

Reviews: