SPT WA-1030E Instruction Manual Download Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation

 

Operation - Electronic Control Models

 

Control Panel 

1.

 

Automatic mode indicator 

2.

 

Cooling mode indicator 

3.

 

Fan mode indicator 

4.

 

Heating mode indicator  

     (For WA-1230H & WA-1030H) 
5.

 

Compressor operation indicator 

6.

 

‘Set temperature’ indicator 

7.

 

‘Room temperature’ indicator 

8.

 

Timer operation indicator 

9.

 

Low ventilation indicator 

10.

 

High ventilation indicator 

11.

 

ON/OFF (power) button 

12. 

Speed (ventilation) button

 

13.    Timer button 

14.   Receiver for Remote Control 

15.   ‘Temperature Down’ button 

16.   ‘Temperature Up’ button 

17.    Display window 
18.   Mode (function) option button

 

WARNING! 

The length of the exhaust pipe is specially 
designed according to the specification of this 
product. 
Do not replace or extend it with your own hose 
as this could cause the unit to malfunction.

 

Turning ON/OFF 

Press the ON/OFF selector; the unit will start to work at its last setting. 

 

Setting Mode/Function 

Press the MODE button to select the required working mode:  Automatic, Cooling, Fan or Heating (Heating is only available for WA-1230H 
& WA-1030H). The green indicator illustrating your selected mode lights up.  It is recommended to select Cooling or Heating mode and set 
your desired temperature, as the Auto mode has a preset temperature (please see below) that cannot be changed.  
The indicators of the functions in progress come on at the same time, e.g.  Cool  and Lo = Cooling mode with Low fan speed. 

 

Auto Mode 

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to: 
• Cool when room temperature is higher than 75°F 
• Heat when room temperature is lower than 68°F (WA-1230H & WA-1030H only) 
If room temperature is between 68°F and 75°F, unit will stay in Fan mode. Again, when in Auto Mode, the temperature settings cannot be 
changed. 

 

Setting the Temperature in Cooling or Heating Mode 

The display window’s default is to display the ambient room temperature.  The green indicator light under RT is on. 
(RT = Room Temperature) 
To set your desired temperature, press the Temperature Up or Down buttons (ranging from 64°F to 90°F).  Each press will increase or 
decrease your set temperature by 1°F.  When pressing the temperature up or down buttons, the window will change to display your set 
temperature. At this time, the green indicator will light under ST (Set Temperature).  Once the temperature up or down buttons is released, 
the window will return to displaying the ambient temperature after a second. 

Note:

  When unit is in the following modes:  Auto, Cool, or Heat - the compressor will cool/heat the room to reach the set temperature.  Once the 

ambient temperature has reached the set temperature, the compressor will stop and unit will run in Fan mode.  To conserve energy, the 
compressor will not start immediately after a couple degrees increase or decrease, but will wait for a 5°F allowance.  For example: 

 

In Cooling Mode with a set temperature of 70°F 

When compressor first stops after reaching 70°F, unit will auto-switch to Fan. 
Compressor will start cooling again when ambient temperature increases to 75°F or above. 

 

In Heating Mode with a set temperature of 72°F 

When compressor first stops after reaching 72°F, unit will auto-switch to Fan. Compressor will start heating again when ambient 
temperature drops to 67°F or below.  

 
In Auto Mode (with preset temperature of 68°F for heat and 75°F for cool) 

Compressor will start cooling again when ambient temperature reaches above 80°F or will start heating when ambient temperature drops 
below 63°F. 
 

Mounting the exhaust pipe 

 
 

 The supplied exhaust hose can be 

extended from I from I foot to 5 feet 
for mounting. It is recommended 
that you use the shortest possible 
length of hose. 
 
 

 Take care to prevent any kink or 

bend in the middle of the exhaust 
hose, as this will trap hot exhaust 
air, which will radiate back into the 
room. 

Installation of the Carbon Filter 

1.

 

Remove the filter frame from the unit. 

2.

 

Separate the filter from the filter frame. 

3.

 

Remove the active carbon filter from its 
plastic bag. 

4.

 

Insert the active carbon filter into  
the filter frame. 

5.

 

Fix the filter by reassembling  
the fixer onto the filter frame. 

6.

 

Re-fit the filter frame inside  
the unit. 

7.

 

It is recommended to replace  
the carbon filter every 3 to 6  
months.. 

Summary of Contents for WA-1030E

Page 1: ...SPTUSA s nominated representative The warranty will be void if the product is modified misused or repaired by an unauthorized person The guarantee after repair or replacement will not be extended beyo...

Page 2: ...Power Cord When the unit is not in use please store the power cord away as shown in Figure 3 Thank you for choosing the portable air conditioner from SPTUSA a leading brand in indoor air treatment We...

Page 3: ...r Do not cover or obstruct the appliance inlet or outlet grilles Figure 2 To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas The...

Page 4: ...uires 2 AAA batteries to operate Regulating the airflow direction Turn the roller on the air vent to control the airflow direction from the vertical louvers Connect the supplied foam strips with the e...

Page 5: ...or Down buttons ranging from 64 F to 90 F Each press will increase or decrease your set temperature by 1 F When pressing the temperature up or down buttons the window will change to display your set t...

Page 6: ...tor comes on To turn off the unit turn the TIMER to the OFF position SPEED Accessories 10 Adaptor for insertion over the hose and into the back of the air conditioner 11 Exhaust Hose Length 14 60 Diam...

Page 7: ...r Use a Shallow Container or Dish 1 Turn off the unit 2 Position a flat container or dish under the drain hole Do not allow the water to drip continuously into the container as it might easily overflo...

Page 8: ...Speed 2 2 Timer 1 12hours 1 12 hours Thermostat 64 F 90 F 64 F 90 F Net Weight 65 lbs 68 lbs Dimensions 15 25 W x 16 5 D x 30 5 H 15 25 W x 16 5 D x 30 5 H Working Temperature Cooling 64 F to 110 F C...

Page 9: ...s Is the unit in auto mode Electronic Mode set to cool or heat and set to proper temperature The unit seems to do little Is there direct sunshine Please close the curtains or blinds Are too many windo...