4
Using a sharp object, pry out the plug buttons(5).
Remove the two Phillips screws(2) that connect
the upper hinge(3) on the
right
.
Lift the door and place it on a padded
surface to prevent from scratching.
Remove the plug(9) and transfer it to the
uncovered hole at the right side
,
press
down
firmly
.
Remove the two bolts(7) that hold the hinge on the lower
right.
Remove the screw-type leveling front leg(8) and transfer it to the right side
as shown
.
Set the door into it's new place
.
Make sure the pin enters the bushing.
Secure the upper hinge(3) to the left side.
Make sure the pin enters the bushing.
Loosely secure the lower left hinge(4)
,
do
not tighten the bolts until the
door is in the closed position and leveled. Insert the plug buttons(5) on the
uncovered holes(right side).
Replace the upper hinge cap(1).
①
⑨
⑧
⑦
⑥
⑤
④
③
②
Plug
Leveling Front Leg
Hinge Plug(Door Frame)
Door Hinge Bolts
Short Leg
Lower Door Hinge
Upper Door Hinge
Door hinge Screws
Door Hinge Cap
①
⑨
⑧
⑦
⑥
⑤
④
③
②