15
4. STARTUP
1. Choose cutting parameters
See chapter 12.
2. Mount proper consumables in the torch
See chapter 10.
3. Open gas valves and adjust pressure to 9 bar.
4. Choose gas mixture setting according to cutting data chart with the gas selector
(1) on the GCU.
See chapter 3.
5. Switch on the key switch (1) on the power source.
See chapter 3. Ventilator and control voltage activates.
6. Push the green button (3) on the power source.
The pump starts and the gas purging cycle starts. Await the green light on the button.
7. Adjust pressure and flow settings on the GCU according to the cutting data
chart.
See chapter 3.
8.
Adjust the cutting current with the current knob (7) according to the cutting data
chart.
See chapter 3.
If the machine is remote controlled via the CNC-interface this setting is made on the
CNC-system or the robot. Consult your system literature for more information.
9. Ready for cutting.