11
2. Gastest switch
Run
Cutting
Preflow
This switch activates the gastest function on the GCU.
Preflow
– Gastest for Preflow
Run
– Normal run mode setting.
Cutting
– Gastest Cutflow
Preflow
– The gas that is used during ignition.
3. Pressure regulator –
With this regulator the preflow plasma gas pressure
(P)
is set
according to the cutting table.
4. Display –
Shows set pressure on preflow plasma.
5. Pressure regulator –
With this regulator the preflow shield gas pressure
(P)
is set
according to the cutting table.
6. Display –
Shows set pressure on preflow shield.
All pressure should be set with gastest active on preflow.
Cutting
– The gas that is used during cutting.
7. Pressure regulator –
With this regulator the Cutting plasma gas pressure
(P)
is set
according to the cutting table.
8. Display –
Shows set pressure on Cutting plasma.
9. Pressure regulator –
With this regulator the Shield plasma gas pressure
(P)
is set
according to the cutting table.
10. Display –
Shows set pressure on Cutting shield.
All pressure should be set with gastest active on Cutting.
Summary of Contents for SPARCIN 4000