background image

Speciality Plumbing Supplies Pty Ltd (SPS) 

Product Manual – Bucket Trap Floor Wastes 

 

Version 7.2 

November, 2010 

Page 2 of 38 

 

A. 

Introduction 

 
Speciality Plumbing Supplies Pty Ltd (“SPS”) is a family-owned business (established 
1978) that specialises in the design, manufacture and distribution of its own range of 
commercial and industrial roof and floor drain systems.  We have worked extremely hard 
over 30 years to earn an enviable reputation for quality, service, expertise, value for 
money and reliability of supply.  SPS products have been used extensively on major 
projects all around Australia but especially along the eastern seaboard, and particularly 
within the greater Sydney area. 
 
SPS offers a large range of basket trap floor wastes for commercial and industrial trade 
waste applications. 
 

 

B. 

Quality Control 

 
SPS has attained quality management certification under ISO 9001:2008 – please see 
Appendix 4 for details.  The main basket trap assemblies and optional grates have been 
certified under ATS5200:040 – please see appendix 5 for details. 
 
SPS basket trap floor wastes are pre-assembled and pre-fitted to ensure proper fit and 
functionality.  Grate assemblies and baskets are designed so that the basket sits snugly in 
the neck of the grate and does not permit any liquid to bypass the basket.  Each 
component is manufactured in accordance with the relevant Australian standard. 
 
SPS basket traps have been approved by Sydney Water since 2001 (approval number 
2001-269). 
 
SPS basket traps have gained a very high level of support from specifiers, plumbing 
merchants and contractors Australia-wide. 
 
 

C. 

Applicability 

 

SPS basket trap floor wastes are designed to intercept and contain debris, such as food 
particles, garbage scraps, rubbish etc. in industrial and commercial applications such as 
restaurants, food processing factories, food preparation areas, garbage rooms, bars etc.  
They are the first stage of the trade waste pre-treatment system and normally operate 
upstream from other devices (such as grease traps) to help ensure that trade waste output 
meets minimum discharge standards. 
 
The essential feature of a basket trap floor waste is its 

strainer system

.  The strainer 

system is comprised of 2 components: 
 
1. 

A strainer basket (removable); and 

2. 

A secondary strainer (fixed). 

 
SPS manufactures 5 different types of strainer systems as per the following table: 

Summary of Contents for BA100S

Page 1: ...PRODUCT MANUAL Version 7 2 BASKET TRAP FLOOR WASTES by SPS Speciality Plumbing Supplies Pty Ltd Unit 9L 175 Gibbes Street Chatswood NSW 2067 ph 02 9416 8031 fax 02 9416 7614 info spsdrains com au...

Page 2: ...e assembled and pre fitted to ensure proper fit and functionality Grate assemblies and baskets are designed so that the basket sits snugly in the neck of the grate and does not permit any liquid to by...

Page 3: ...4SS 304 or 316SS Lower body cast iron grate assemblies 304 or 316SS Lower body cast iron or 316SS grate assemblies 304 or 316SS 304 or 316SS moveable plate ferritic SS Pitch refers to the distance bet...

Page 4: ...for unrestricted water flow Flow Rates of Grate Assemblies assuming a 20mm head of water above grate Round grates litres per second 112mm 0 95 135mm 1 9 sheet vinyl 150mm 2 2 155mm 2 0 sheet vinyl 220...

Page 5: ...5 of 38 Strainer System 2 Push in Grate Options Type Ref Available Materials Load Rating AS3996 2006 Round 130mm p 14 304 or 316 Stainless Steel Class B Round 150mm p 15 304 or 316 Stainless Steel Cl...

Page 6: ...mm p 18 304 or 316 Stainless Steel Class B Round 225mm p 19 304 or 316 Stainless Steel Class B Square 150mm p 20 304 or 316 Stainless Steel Class B Square 200mm p 21 304 or 316 Stainless Steel Class C...

Page 7: ...or 316 Stainless Steel Class B Round 300mm p 24 304 or 316 Stainless Steel Class C Square 200mm p 25 304 or 316 Stainless Steel Class C Square 225mm p 26 AB2 Aluminium bronze 316 Stainless Steel Clas...

Page 8: ...ate drops into place providing a very solid tamper resistant secondary strainer The plate contains very small perforations 1 5mm thereby preventing virtually any solids from entering the waterway But...

Page 9: ...ight having regarding to the any topping to be applied to the slab 4 Ensure that grate is protected during concrete pour for example by covering with duct tape The tape should be trimmed to upper edge...

Page 10: ...itical aspect of basket trap floor wastes In order to function properly basket trap floor wastes require regular cleaning of the basket and inspection of the secondary strainer How often this needs to...

Page 11: ...vailable from SPS The relevant product codes are contained in the following tables Strainer System Replacement Components Strainer system Product Code Basket Secondary strainer 1 Compact SB75 n a 2 Pu...

Page 12: ...ollowing practices will help minimise risks to health 1 The strainer system should be regularly inspected and cleaned to minimise the build up of decaying food matter 2 Grates should be scrubbed with...

Page 13: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 13 of 38 Appendix 1 Specification Drawings Strainer System 1 Compact...

Page 14: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 14 of 38 Appendix 1 Specification Drawings Strainer System 2 Push in 130mm round grate...

Page 15: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 15 of 38 Appendix 1 Specification Drawings Strainer System 2 Push in 150mm round grate...

Page 16: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 16 of 38 Appendix 1 Specification Drawings Strainer System 2 Push in 150mm square grate...

Page 17: ...eciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 17 of 38 Appendix 1 Specification Drawings Strainer System 2 Push in 135mm vinyl floor gra...

Page 18: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 18 of 38 Appendix 1 Specification Drawings Strainer System 3 Height adjustable Shallow Body 150mm r...

Page 19: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 19 of 38 Appendix 1 Specification Drawings Strainer System 3 Height adjustable Shallow Body 225mm r...

Page 20: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 20 of 38 Appendix 1 Specification Drawings Strainer System 3 Height adjustable Shallow Body 150mm s...

Page 21: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 21 of 38 Appendix 1 Specification Drawings Strainer System 3 Height adjustable Shallow Body 200mm s...

Page 22: ...mbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 22 of 38 Appendix 1 Specification Drawings Strainer System 3 Height adjustable Shallow Body 155mm viny...

Page 23: ...y Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 23 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 225mm ro...

Page 24: ...y Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 24 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 300mm ro...

Page 25: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 25 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 200mm squ...

Page 26: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 26 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 225mm squ...

Page 27: ...Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 27 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 300mm squ...

Page 28: ...lumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 28 of 38 Appendix 1 Specification Drawings Strainer System 4 Height adjustable Deep Body 220mm sheet...

Page 29: ...ty Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 29 of 38 Appendix 1 Specification Drawings Strainer System 5 Smart Secondary Strainer 150mm squa...

Page 30: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 30 of 38 Appendix 2 Load Tests...

Page 31: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 31 of 38 Appendix 2 Load Tests...

Page 32: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 32 of 38 Appendix 2 Load Tests...

Page 33: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 33 of 38 Appendix 2 Load Tests...

Page 34: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 34 of 38 Appendix 2 Load Tests...

Page 35: ...s or faulty workmanship on the part of the manufacturer 2 The guarantee does not cover failures by a misuse b neglect c normal wear and tear d accidental breakage e use of the product in an inappropri...

Page 36: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 36 of 38 Appendix 4 Quality Management System Certification...

Page 37: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 37 of 38 Appendix 5 Product Certification...

Page 38: ...Speciality Plumbing Supplies Pty Ltd SPS Product Manual Bucket Trap Floor Wastes Version 7 2 November 2010 Page 38 of 38 Appendix 5 Product Certification...

Reviews: