background image

Contents:

1   Introduction 

1

1   Introduction 

1

2   Installation 

2

2   Installation 

2

2.1 

Power supplies 

2

3   Channel information 

3

3   Channel information 

3

4   Block diagram 

4

4   Block diagram 

4

SPRINT ELECTRIC LTD.

 does not 

accept any liability whatsoever for 

the installation, fitness for purpose or 

application of its products. It is the users 

responsibility to ensure that the unit is 

correctly used and installed.

Health and Safety at Work

 

Devices constitute a safety hazard. It is 

the responsibility of the user to ensure 

compliance with any Acts or By-Laws 

in force. 

ONLY skilled persons should 

install this equipment.

Disposal

This product contains materials that are consignable waste under the Hazardous Waste 

Regulations 2005. Metal and plastic materials can be recycled, however, disposal of the 

printed circuit board requires compliance with all valid environmental control laws.

Products that must be recycled in accordance with the WEEE Regulations are 

marked with the symbol opposite. Contact us when recyling the product.

Summary of Contents for Option CON113

Page 1: ...HG105408EN00 Issue 1 01 2022 World Class Design World Class Function 30 Years Expertise in Industrial Motor Control Product Manual BUFFER BOARD Option CON113 ...

Page 2: ...rs and operators understand the included WARNINGS CAUTIONS and NOTES which alert the user to safety issues COMPLY WITH WARNINGS AND CAUTIONS AT ALL TIMES Each of these carries a special meaning and should be read carefully WARNING A WARNING is given when non compliance with the warning may result in personal injury and or equipment damage CAUTION A CAUTION is given when non compliance with the cau...

Page 3: ...UIPMENT DAMAGE HAZARD We thoroughly test our products However before installation and start up inspect all equipment for transit damage loose parts packing materials etc Installation must observe the required environmental conditions for safe and reliable operation In a domestic environment this product may cause radio interference requiring adequate measures to be taken Obtain the permission of t...

Page 4: ...lth and Safety at Work Devices constitute a safety hazard It is the responsibility of the user to ensure compliance with any Acts or By Laws in force ONLY skilled persons should install this equipment Disposal This product contains materials that are consignable waste under the Hazardous Waste Regulations 2005 Metal and plastic materials can be recycled however disposal of the printed circuit boar...

Page 5: ...intain dancer position Features Specification Mains powered Supply voltage 110 or 240 Vac Adjustable response rate Dimensions W 96 mm H 100 mm D 45 mm Internal preset and externally adjustable references 10 0 10 V feedback input and output Fully isolated circuit Follow these installation instructions and the drive s Product Manual to maintain EMC compliance Further measures may be necessary EMC be...

Page 6: ...ensions 10K AC POWER IN 110 V or 230 V ANTI CLOCKWISE MID WAY CLOCKWISE Terminals 1 6 Terminals 7 12 Terminals 19 24 Terminals 13 18 OFFSET SCALE RAMP RATE CH3 CH4 CH5 ON 90 mm 86 mm 5 mm 5 mm Fixing screws M4 x 20 mm J1 J2 B C D A T9 INTEGRATOR PRESET INPUT E G OUTPUT Z1 Z2 2 Installation 2 2 Installation Installation WARNING ELECTRIC SHOCK HAZARD Disconnect the mains supply before working on the...

Page 7: ...nnel information 3 3 Channel information Channel information Channels Default operating mode CHANNEL 1 Differential amplifier having unity gain Fit extra resistors to the board to change the gains CHANNEL 2 CHANNEL 3 Integrator circuit OFFSET Use to zero integrator drift usually set mid way unless factory preset and sealed preset SCALE Set TOTAL GAIN K2 A CHANNEL 4 Summing amplifier OFFSET Use as ...

Page 8: ...DIFFERENTIAL AMPLIFIER CHANNEL 3 SCALE OFFSET preset CHANNEL 4 SCALE OFFSET CHANNEL 5 RAMP RATE DANGER ELECTRIC SHOCK RISK 470K Z2 Z1 100K 4M7 0 1 µF 100R J2 100K 100K 100K 10K 100K 50K 50K 12 12 cw for ve OFFSET SCALE cw to reduce gain IC2 100K close to preset integrator input to integrator output OFFSET PRESE internal refere offset 10K external reference pot AC POWER IN 110 V or 230 V 1 µF 47K 4...