14
Options
8
8 Options
Options
The 200XLV provides the following extra functions (that may require you to supply additional
parts). Access these by removing the terminals and cover from the unit.
8.1 PID feedback
Change the input amplifier feedback network to P (Proportional), PI (propor integral)
or PID (propor in derivative) mode by using the 3-position top jumper.
When using PI or PID mode, the feedback time constant is approximately 100 ms, and the
proportional gain is 3.
1
2
3
4
5
6
7
8
9
Top proportional gain (PG) link
Top jumper positions:
PID
PI
P
P:
PID
PI
P
PI:
PID
PI
P
PID:
RAMP CAPs (with large pads to allow top soldering)
Bottom proportional gain (PG) link
Bottom jumper positions:
Armature voltage (AV) control
Tacho or position feedback
PID
AV
PID
AV
Auxiliary trip
INT CAP
Figure 18 Jumper and link positions