Clipper Test Probe                        Operating Instructions

 

 

P/N CLP1500V15A1          V1.3 

Page 8 

 

potential divider effect.  With a high impedance probe, this effect is 

negligible. 

A typical OUTPUT connection looks like this: 

 

 

 

 

 

MODE SWITCH 

Range Switch 

The Range switch sets the actual clipping voltage. 

LO Range: Maximum Output Voltage 2V (nominal) 

HI Range: Maximum Output Voltage 12V (nominal) 

Load current is not affected, 

 

Repairs / Service / Calibration 

For high voltage protection, the internal electronics is sealed with a potting 

compound. There are no user serviceable parts inside, no repairs are 

possible. 

 

 

Clipper Test Probe                        Operating Instructions

 

 

P/N CLP1500V15A1          V1.3 

Page 9 

 

Because of the unique “pass-through” design, there is no need to calibrate 

the device. 

IP Protection: 

The Clipper design and intellectual property is protected with an 

International Patent (pending at time of writing, July 2014).  

Recycling: 

The Clipper can be recycled with the normal electronic recycling systems. 

There are no hazardous materials included (such as batteries or Lead).  

Springburo GmbH is registered with the ear-stiftung in Germany, which 

regulates the recycling of consumer and Industry electronic products. 

Registration Number:  

DE 77429530

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CLIPPER

Page 1: ...y Information Because of its application area the measurement of high voltages it is particularly important to read the connection instructions and safety instructions listed below EC Declaration of Conformity The product is marked with this symbol to indicate that it conforms to the applicable European Union requirements per Low Voltage Directive LVD 2006 95 EC Compliance was demonstrated to the ...

Page 2: ...robe with no isolation between IN and OUT Under normal conditions no voltages above 15VDC appear on the output terminals but be aware that under fault conditions it may be possible to have the IN voltages present on the OUT and the Probe must be handled with this consideration ALWAYS keep a safe distance between the DUT and the IN OUT terminals before powering on the DUT Under NO circumstances tou...

Page 3: ...o SMA Male 12GHz 50Ω 2 2 SMA BU P 50Ω 4 3 SMA BNC Plug 50Ω 1 4 SMA BNC Socket 50Ω 1 Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 5 Fig 2 The accessories are provided to allow different connection possibilities Operating Details Overview The Clipper is operated as follows Firstly make sure DUT is switched OFF INPUT 1 Connect Solder terminals to SMA 2 Solder connections to DU...

Page 4: ...lipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 7 Fig 4 Electrical Diagram showing typical connection schematic Notes Inclusion of a sense resistor in the circuit will reduce the accuracy of the Clipper Measurements must be made across the DRAIN SOURCE directly for best results Current drawn by the clipper is a constant 350μA independent of Input Voltage Keep connections short ...

Page 5: ...g compound There are no user serviceable parts inside no repairs are possible Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 9 Because of the unique pass through design there is no need to calibrate the device IP Protection The Clipper design and intellectual property is protected with an International Patent pending at time of writing July 2014 Recycling The Clipper can be r...

Page 6: ...l 49 6352 78998 0 www admess de China Hong Kong REVEL Electronics Co Ltd Hong Kong www revel com hk Taiwan and Singapore INDUSTRADE Co Ltd Taiwan www industrade com tw USA Canada SAELIG Company INC www saelig com UK Ireland IMEX Ltd www imex co uk Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 11 Manufacturer Springburo GmbH Theodor Ludwig Strasse 24 D 79312 Emmendingen Germa...

Reviews: