Springburo CLIPPER Operating Instructions Manual Download Page 3

Clipper Test Probe                        Operating Instructions

 

 

P/N CLP1500V15A1          V1.3 

Page 4 

 

Applications 

The Clipper is perfect for observing the Rds(on) of a switched FET, or IGBT. 

With an Oscilloscope set to 200mV /division, the stability of Rds(on) over a 

range of say 200mΩ to 1Ω can be clearly seen in good resolution, while the 

power transistor is switching.

 

More details and full specifications and application help can be found on 

our Website:  

www.springburo.weebly.com

 

Contents of Packing

 

The Clipper and accessories are delivered in an Aluminium case as shown in 

Fig 1: 

 

 

 

 

 

 

 

 

Accessory List (ref Fig 2): 

Pos 

Type 

Spec 

Qty 

SMA to SMA Male 

12GHz, 50Ω 

SMA BU P 

50Ω 

SMA BNC Plug 

50Ω 

SMA BNC Socket 

50Ω 

 

Clipper Test Probe                        Operating Instructions

 

 

P/N CLP1500V15A1          V1.3 

Page 5 

 

Fig 2: The accessories are provided to allow different connection 

possibilities. 

 

 

 

 

 

 

 

Operating Details 

Overview 

The Clipper is operated as follows: 

Firstly, make sure DUT is switched OFF !!

 

INPUT: 

1: Connect Solder terminals to SMA 

2: /- connections to DUT 

3: Screw SMA onto Clipper using SMA to SMA adapter 

 

OUTPUT: 

4: Connect 10X scope probe to BNC terminal of Clipper 

5: Set Range switch to either HI (12V) or LO(2V). 

6: Adjust Oscilloscope to correct sensitivity (e.g. 200mV or 2V/Div) 

depending on Range setting. 

7: If using current probe, set Oscilloscope channel accordingly, and use 

MATH function to display Rds(on) = Vds/Ids 

8: Switch on DUT and observe Rds(on) 

 

Summary of Contents for CLIPPER

Page 1: ...y Information Because of its application area the measurement of high voltages it is particularly important to read the connection instructions and safety instructions listed below EC Declaration of Conformity The product is marked with this symbol to indicate that it conforms to the applicable European Union requirements per Low Voltage Directive LVD 2006 95 EC Compliance was demonstrated to the ...

Page 2: ...robe with no isolation between IN and OUT Under normal conditions no voltages above 15VDC appear on the output terminals but be aware that under fault conditions it may be possible to have the IN voltages present on the OUT and the Probe must be handled with this consideration ALWAYS keep a safe distance between the DUT and the IN OUT terminals before powering on the DUT Under NO circumstances tou...

Page 3: ...o SMA Male 12GHz 50Ω 2 2 SMA BU P 50Ω 4 3 SMA BNC Plug 50Ω 1 4 SMA BNC Socket 50Ω 1 Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 5 Fig 2 The accessories are provided to allow different connection possibilities Operating Details Overview The Clipper is operated as follows Firstly make sure DUT is switched OFF INPUT 1 Connect Solder terminals to SMA 2 Solder connections to DU...

Page 4: ...lipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 7 Fig 4 Electrical Diagram showing typical connection schematic Notes Inclusion of a sense resistor in the circuit will reduce the accuracy of the Clipper Measurements must be made across the DRAIN SOURCE directly for best results Current drawn by the clipper is a constant 350μA independent of Input Voltage Keep connections short ...

Page 5: ...g compound There are no user serviceable parts inside no repairs are possible Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 9 Because of the unique pass through design there is no need to calibrate the device IP Protection The Clipper design and intellectual property is protected with an International Patent pending at time of writing July 2014 Recycling The Clipper can be r...

Page 6: ...l 49 6352 78998 0 www admess de China Hong Kong REVEL Electronics Co Ltd Hong Kong www revel com hk Taiwan and Singapore INDUSTRADE Co Ltd Taiwan www industrade com tw USA Canada SAELIG Company INC www saelig com UK Ireland IMEX Ltd www imex co uk Clipper Test Probe Operating Instructions P N CLP1500V15A1 V1 3 Page 11 Manufacturer Springburo GmbH Theodor Ludwig Strasse 24 D 79312 Emmendingen Germa...

Reviews: