background image

Installing the Tanks

60) Connect another 
corrugated pipe to the other 
end of the pre-plumb.

61) Connect the other end to the 
outlet on the softener tank.

59) Connect the other end of the 
corrugated pipe to the inlet on 
the softener tank

Questions? Call (800)-589-5592

14

Whole House Filter and Water Softener

Your system connections should look similar to this.

From Water 

Main

Into Home

Summary of Contents for CSS+

Page 1: ...N FRI 9AM 6PM EST 800 589 5592 WWW SPRINGWELLWATER COM You get the best of both worlds when you combine the benefits of our traditional salt based water softener and our whole house water filter which uses the highest quality coconut shell catalytic carbon that targets the contaminants that we find in our water supplies today ...

Page 2: ...tions Yoursystemconfiguration may vary depending on installation area Electronic Head for SS Questions Call 800 589 5592 2 Whole House Filter and Water Softener Setup And Installation Pre Filter Gasket and Lube Spanner Wrench Sediment Filter Hose Bib Assembly Mounting Bracket Tank Head for CF Softener Tank Tank 1 Tank 2 1 inch 24 inch Long Corrugated Water Connectors x4 1 inch 3 inch long PVC Nipp...

Page 3: ...until the tank stands vertically and fits snuggly into the tank boot PLEASE READ INSTRUCTIONS FULLY PRIOR TO ATTEMPTING INSTALLATION Be sure to follow all applicable plumbing codes The system must be installed on a main water supply line Caution Do not install on well water unless you have spoken to a customer service representative first Whole House Filter and Water Softener ...

Page 4: ...ures 36 120 F Pre Filter Change Replacement Every 6 9 Months Media Change Replacement Every 6 years or 1 Million Gallons SS1 Tank Width 9 Tank Height 48 57 with Head Flow Rate 11 GPM Service Connection Size 3 4 Backwash Rate 2 GPM Operating Pressure 25 80 PSI Operating Temperatures 36 120 F pH Range 6 5 10 Grain 32k Brine Tank 18 w x 33 h Whole House Filter and Water Softener SS4 Tank Width 10 Tan...

Page 5: ...ed Questions Call 800 589 5592 5 ONCE THE HEAD ATTACHES TO THE PIPE INSIDE THE TANK IT IS PERMANENT Do not attempt to unscrew or remove the head from the tank or it will cause the components within the tank to separate causing damage and potentially cause resin to seep from the tank into your home plumbing 1 Unscrew the cap on top of the carbon filter tank 8 Use your feet around the boot to add gr...

Page 6: ... connections securing the bypass valves 12 Attach and tighten a MNPT Fitting onto the connections on each of the bypass valves 13 Use the hose bib to attach the lawn hose to the inlet on the first tank Ensure the bypass is off to allow water flow through the tank 14 Turn on the water to the hose halfway until water exits the tank Turn off the water and disconnect the hose and hose bib 15 Switch th...

Page 7: ...onnect the hose to the hose bib assembly 19 Run water through the tank until the water runs clear 20 Switch the hose and hose bib to the outlet side now and flush with water in the opposite direction until the water runs clear Bypass Operation Bypass on water does not flow through tank Bypass off water flows through tank Questions Call 800 589 5592 7 Whole House Filter and Water Softener Tank 1 No...

Page 8: ...the Sediment Filter into the pre filter Housing 22 The O ring will now be laid into the groove around the top of the pre filter Housing tank 23 Squeeze lubricant onto the O ring then spread it using your finger 24 Flip the O Ring over and lubricate the opposite side as well 26 Replace the lid and fully tighten it Questions Call 800 589 5592 8 Whole House Filter and Water Softener ...

Page 9: ...he inlet of the pre filter Mark your holes for pre drilling 30 Use a 3 16 drill bit to pre drill the holes for the pre filter mounting bracket 31 Use 4 of the provided bolts and washers to secure the bracket to the wall using a 1 2 socket Spanner Wrench Mounting Bracket 1 inch 3 inch long PVC Nipples x3 Plumbers Tape 1 inch 24 inch Long Corrugated Water Connectors x1 1 Inch PVC Shut Off Valve Wren...

Page 10: ...he threaded adapter for the opposite end of the pre plumb towards the tank connections NOTE Plumbers tape will need to be applied to every thread when connecting all corrugated pipes 37 Connect the PVC shut off valve onto the threaded adapter on the incoming water supply 39 Connect a corrugated pipe to the PVC nipple 40 Connect the other end of the corrugated pipe to the inlet on the pre filter Qu...

Page 11: ...crew the cap on top of the softener tank 42 There is a blue cap inside that also needs to be removed Both caps can be discarded 43 Locate the opening at the bottom of the electronic head 44 Align the opening on the bottom of the tank head with the pipe inside the tank 45 Press the tank head down to allow the threads to catch 46 Turn the tank head clockwise until it is fully tightened Hand tight is...

Page 12: ...ns securing the bypass valves 47 Install the blue bypass valves onto the connections on the electronic head 50 Attach and tighten a MNPT Fitting onto the connections on each of the bypass valves 51 Apply plumbers tape to both MNPT Fittings Questions Call 800 589 5592 12 Whole House Filter and Water Softener Installing the Softener Electronic Head ...

Page 13: ...ipe to the inlet on the carbon filter tank 56 Position the softener tank next to the carbon filter tank with its connections facing back Carbon Filter Tank This step will require the materials listed below Plumbers Tape Wrench 1 inch 24 inch Long Corrugated Water Connectors x3 52 Apply plumbers tape to the inlet and outlet connections on the carbon filter tank Questions Call 800 589 5592 13 58 Con...

Page 14: ...b 61 Connect the other end to the outlet on the softener tank 59 Connect the other end of the corrugated pipe to the inlet on the softener tank Questions Call 800 589 5592 14 Whole House Filter and Water Softener Your system connections should look similar to this From Water Main Into Home ...

Page 15: ...ut of the tank head 66 Align the hoes clamp over the connection then align the screw on the hose clamp so that it runs parallel to the connection on the drain valve Tighten the clamp This step will require the materials listed below 62 Locate the drain on the left side of the electronic tank head on the softener tank Questions Call 800 589 5592 15 68 Insert the blue tab to lock the drain valve bac...

Page 16: ...in pace The excess can then be trimmed off the zip ties 73 The power cord will be connected to the connection on the far left beneath the electronic tank head 74 The power adapter will then be plugged into a power supply that isn t controlled by a switch Questions Call 800 589 5592 16 Whole House Filter and Water Softener Additional Softener Head Steps IMPORTANT Ensure the drain lines you installe...

Page 17: ...ps to secure the drain line to the drainpipe 82 Remove the lid from the brine tank This step will require the materials listed below 78 Position the brine tank next to the softener tank with the drain valve pointing towards the softener Questions Call 800 589 5592 17 84 Release the regen line from the softener head by removing the zip ties Use care not to damage the line Whole House Filter and Wat...

Page 18: ...brine well 85 Insert the regen line into the brine tank through the opening above the drain line you installed earlier 88 The brine tank will need to be filled with 4 to 5 bags of salt pellets 90 The system can now be tested Questions Call 800 589 5592 18 Whole House Filter and Water Softener Fill 89 The lid to the brine tank cab be replaced Installing the Brine Tank ...

Page 19: ...w through the tank bypasses 99 Allow water to run through the system for 5 10 minutes It is normal to see a small amount of sediment during this time Questions Call 800 589 5592 19 Whole House Filter and Water Softener Off Bypass Bypass 95 Turn on the water to the home and inspect the shut off valve for any leaks 97 If no leaks are detected from the bypass turn off the bypass to the carbon filter ...

Page 20: ...er Softener Softener Tank Already Installed Tank 2 Mobile Device 101 Open the app and select your softener from the list 102 Tap Time of Day on Unit to change the time 103 Select OK to set the time on to the same time as your device 104 To modify the regen time tap on that tile 2 00am is the default time 105 Note You want the system to regen while water is not being used 106 Tap Water Hardness to ...

Page 21: ...nced Settings 110 Tap Regeneration Day Override 111 Change the value to 14 days 112 Tap Reserve Capacity 113 Change the value to 10 114 Tap Resin Grains Capacity 115 Change the value to 32 for 32 000 116 Select Brine Refill 117 Change the value to 8 min 118 Recap of settings for SS1 system Next Steps 114 to 118 are for SS1 Systems Skip to step 119 for SS4 systems ...

Page 22: ...0 minutes 123 Correct values for SS4 system 124 Tap the menu icon in the upper left hand corner 125 The next step will force you to regen your system During this time you will not be able to use your water for 90 minutes 126 Select Regenerate Now 127 Select OK from the pop up and the system will regen for 90 minutes 128 Once the regen is done your system is ready to use 119 Tap Resin Grains Capaci...

Page 23: ... or that the O ring became bunched Slowly unthread the head from the tank approx half a rotation You only need to expose a small gap between the tank collar and the tank head Reconnect the tank to the system and proceed back to page 19 to test the system again Questions Call 800 589 5592 23 Fully re tighten the head onto the tank The O ring will now be able to reseat Whole House Filter and Water S...

Reviews: