background image

2

3

Function

Spring USA’s 1800

-watt, LoPRO

Induction Ranges are portable, 

product cooking or holding ranges intended for countertop use.   Each 
range features a durable, all-black housing with touch controls on the 
glass surface.   

Before You Begin

To ensure safe operation, read the following instructions in their 
entirety.

Warning is used to indicate the presence of a hazard that can cause 
severe personal injury, death, or substantial property damage if the 
warning is ignored. 

Caution is used to indicate the presence of a hazard that will or can 
cause minor personal injury or property damage if the caution is 
ignored. 

NOTICE

Notice is used to note information that is important but not
hazard-related.

To reduce risk of injury or damage to the equipment:

Plug only into grounded electrical outlets matching the nameplate 
rated voltage.

Do not power the equipment with extension cords, power strips, or 
multipurpose sockets. 

Equipment should only be used in a flat, level position.

Do not obstruct or cover the equipment in any way when in use.

Do not operate unattended. 

Do not leave an empty vessel on the equipment when in use.

Closely supervise equipment operating in public areas and/or around 
children.

Do not operate if equipment has been damaged or is malfunctioning 
in any way. 

Keep equipment and power cord away from open flames, electric 
burners or excessive heat.

Unplug equipment and let it cool before cleaning.

Unplug when not in use.

Item #

Voltage

Phase

Hertz

Watts

Amps

Plug

SM-1800LP

110-120

1

60

1800

15

NEMA 5-15P

SM-1800LP-D

110-120

1

60

900 x 2

7.5 x 2

NEMA 5-15P

Electrical Requirements:

Installation

Inspect all parts of the induction range prior to installation and use.  If 
the unit is damaged, do not use.  Contact a supplier for a replacement.  

To prepare the induction range for use, simply place the unit on a flat, 
level surface.  Ensure the installation location has dedicated power.  

There must be at least 1.2” (3 cm) of space available around the 

induction range for proper ventilation. 