Page 1: ...10 TankJet AA290E EP Series Tank Cleaner USER GUIDE spray com MI AA290E EP TankJet AA290E EP Electric Motor Driven Tank Cleaner ...

Page 2: ...ufacturer s Operation Maintenance Manual is included with this tank washer as a separate manual since important safety precautions pertaining to the installation and operation of the motor itself are included SPECIFICATIONS Liquid Pressure 250 psi 17 bar max Flow Rates Up to 284 gpm 1075 l m Liquid Temperature 200 degrees F 93 degrees C max Electrical Motor 120 Volt AC or 240 Volt AC Tank Diameter...

Page 3: ...3 DATA SHEETS ...

Page 4: ...4 ...

Page 5: ...ower supply to the conduit connection hole as shown on datasheet 290E EP and verify that the nozzle hub rotates clockwise when viewed from the nozzle hub end Connect the liquid line to the inlet connection of the liquid inlet body WIRING Route cabling through the most appropriate conduit entry making sure that cables will not foul on the cover assembly or internal components after refitting Refer ...

Page 6: ...dup of static charge between the tank and the tank washer parts which could cause a sudden discharge of current with a resultant explosion or fire You may be killed or seriously injured if you do not follow these instructions HIGH IMPACT SPRAYS This tank washer may be equipped with solid stream nozzles which concentrate the flow energy into a small area for maximum impact and cleaning efficiency O...

Page 7: ...d since they may scratch and severely damage the orifice 3 If the nozzles need replacement obtain new nozzles 4 Replace spray nozzles 30 in nozzle hub 29 by tightly screwing them in REMOVAL AND REPLACEMENT OF ELECTRIC MOTOR DRIVE ITEM 13 ON PARTS LIST PL 290E EP 1 Unscrew clockwise left hand thread rotary housing plug 31 and slide nozzle hub bushings 23 and nozzle hub 29 off the rotary housing 22 ...

Page 8: ...ub assembly 20 Remove any foreign material from the bevel gear teeth 5 Remove worn bushings 23 and 21 from the rotary housing 22 6 Remove worn shaft bushing 26 and O ring 24 from the lower bushing retainer worn shaft bushing 25 and replace with new parts 7 Inspect shaft 13 for wear and replace shaft if worn 8 Reassemble unit by installing split bushing 21 nearest the gear 20 9 Hold split bushing 2...

Page 9: ...9 PARTS LIST ...

Page 10: ...10 MAINTENANCE RECORD Date Procedure Performed ...

Page 11: ...ir 1996 components Hydraulics EN12100 1 Safety of machinery Basic concepts general principles 2003 for design Part 1 Basic terminology methodology EN12100 2 Safety of machinery Basic concepts general principles 2003 for design Part 2 Technical principles EN ISO 14121 1 Safety of machinery Risk assessment Part 1 Principles 2007 ASME B31 1 ASME Boiler and Pressure Vessel Code 2001 I hereby declare t...

Page 12: ...North Avenue and Schmale Road P O Box 7900 Wheaton IL 60187 7901 Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 www spray com MI AA290E EP Spraying Systems Co 2019 ...