OPERATION
Refer to drawings on pages 9 thru 11 for parts list.
INSTALLATION
The TankJet
®
78 is easy to install. Both the TankJet 78 and
78D connect to a supply tube with a simple retaining clip.
There are two different size options for inlet connections to
the TankJet 78 and 78D; 1-1/2" (standard) and 2". The supply
line should be a standard smooth bore 16 gauge (.065" thick)
stainless steel tube of the appropriate size. A Ø13/64" or
Ø5mm hole should be drilled thru the supply tube according
to the diagram below.
Slip the supply tube into the inlet of the unit, aligning the
holes. Insert the retaining clip and swing it down until it
locks. It should wrap around the neck of the inlet, but still fit
loosely.
The TankJet 78 unit will only operate properly in the
suspended vertical position (inlet at top), however, the
TankJet 78D may be operated in any orientation.
NOTE: in order to maintain 3-A sanitary compliance, all
units intended for CIP must be mounted in the suspended
vertical position in order to ensure proper drainage. Other
orientations must be either returned to the suspended
vertical position or removed after operation and cleaned
out-of-place.
Inlet Size
“A”
1-1/2"
11/16" (17.4mm)
2"
15/16" (23.8mm)
Specifications
Inlet Connection:
1½" or 2" slip-fit
Operating Pressure Range:
20 - 100 psi (1.4-7 bar)
Max. Operating Temp:
180° F (82° C)
Flow Capacity:
35 - 110 gpm (132-416 l/min) (Based on Models)
Head Rotation Speed:
15 - 35 rpm
Effective Cleaning/Dia.:
To 45 ft. (13.7 m) maximum
Installation Hole Dia.:
TJ78: Ø5 ¾" (Ø146 mm), TJ78D: Ø7 ⅝" (Ø194 mm)
Approximate Weight:
TJ78: 15 lbs. (6.8 kg), TJ78D: 18 lbs. (8.6 kg)
Recommended Strainer:
100 Mesh (not included)