![Spotwave Wireless SpotCell 100 User Manual Download Page 32](http://html1.mh-extra.com/html/spotwave-wireless/spotcell-100/spotcell-100_user-manual_1351213032.webp)
T
ROUBLE
S
HOOTING
I
NFORMATION
24
SpotCell 100, Release 1.0
4.
Status
: While optimizing the DDU for installation, you found that
the LED turned green in multiple locations, indicating each had
appropriate signal strength. How do you determine which location
is optimal for the DDU?
Action
: Look at the signal level indicated on the display on the
bottom of the SCU each time the green light appears on the DDU
during alignment. Mount the DDU in the location as indicated
having the highest signal level. Figure # below shows an example of
a displayed signal strength.
Figure 3.1:Displayed signal strength.
5.
Status
: If the SpotCell system seems to work intermittently, or
exhibits unexpected behavior.
Action
: If 50m of RF cable is connecting the SCU and DDU,
operation can not be guaranteed if the wire supplying power to the
SCU is longer than 21feet. With the standard 25m cable between
the SCU and DDU it can be extended up to 60ft. While the
provided power supply and wire may be cut shorter, ensure it falls
within the confines described above if it must be made longer.
TO BE UPDATED
Summary of Contents for SpotCell 100
Page 4: ...iv SpotCell 100 Release 1 0...
Page 27: ...Spotwave Wireless Inc 21...
Page 28: ...MOUNTING 22 SpotCell 100 Release 1 0...
Page 30: ...DISPLAYED INFORMATION 22 SpotCell 100 Release 1 0...
Page 36: ...TROUBLE SHOOTING INFORMATION 28 SpotCell 100 Release 1 0...
Page 42: ...SYSTEM SPECIFICATIONS 32 SpotCell 100 Release 1 0...
Page 46: ...INSTALLATION SAFETY REGARDING HAZARD OF SHOCK 36 SpotCell 100 Release 1 0...