background image

COM 50 F

ACCESSORIES FOR COMBI 50 Fresnel

Colour filter frame

TC S50

4 leaf barndoor

PL 4  S50

Safety rope

FUNE

Theatre C-hook in black painted steel for 30 to 50 mm diameter tubes

GAC

TV C-hook  in die-cast aluminium (PIVOT DIN adapter required)

A8

29 mm / M10 spigot adapter

PIVOT DIN

Aluminium clamp for 50 mm diameter tubes

HC/500

Scrolling colour changer, DMX 512 - 0/10V controlled

on request

CHANGING THE LAMP

Open the front lens door 

 sliding the lock lever 

④ 

towards the right.

- Verify that the light centre, the power and the voltage 

of the new lamp are the same as the old one.

- Change the lamp avoiding to touch the quartz bulb. 
- Close gently the door and verify that it is properly 

locked.

TYPE OF LAMP

See lamp table.

WARNING

For safety reasons always disconnect 

the projector from the mains before 
opening it to change the lamp or 

servicing.

Always connect the projector to a 

mains protected by a suitable electric 
fuse according to the instructions 
supplied by the manufacturer of the 
lamps in use.

FOCUS AND REGULATION

The luminaire should be at the minimum distance  from 

the object it is illuminating, as indicated on the label.

Using the side handle 

 it is possible to loosen the 

projector and adjust the tilt. For pan adjustmernt 
rotate the projector on the suspension hook. 
By turning knob 

, the lamp tray is shifted forward 

or backward to respectively widen or narrow the light 
beam.

CLEANING

For best projector performance, both the lens and the 
reflector must be periodically cleaned.
Always remember to disconnect the projector from the 
mains and let the lamp cool before proceeding to any 
cleaning or servicing operations. 

MAINTENANCE

The projectors must be serviced at least once a year to 
check  the  integrity  of  their  electrical  and  mechanical 
parts.  For  this  purpose,  you  should  conctact  only  a 
qualified dealer, to ensure proper service.

RECYCLING

The product must be recycled or disposed of, 
according to Directive 2002/96/CE.

6

Summary of Contents for combi 50 Fresnel

Page 1: ...Manuale utente User manual combi 50 Fresnel cod COM 50 F...

Page 2: ...ht srl non potr essere ritenuta responsabile di danni derivanti dalla non osservanza di dette istruzioni SAFETY WARNING Before using this product read carefully the following instructions Spotlight sr...

Page 3: ...ello per fune di sicurezza proiettore Pomolo per regolazione posizione lampada Maniglia per regolazione inclinazione faro INDICAZIONI GENERALI Il proiettore in Vs possesso risponde alle Direttive Euro...

Page 4: ...fare riguardo alla rotazione dell asse verticale facendolo ruotare sul perno di aggancio Ruotando il pomello si fa avanzare e retrocedere la slitta con la lampada rispettivamente per allargare e strin...

Page 5: ...ty bond attachment Lamp position adjustment knob Lever handle for tilt regulation INTRODUCTION The luminaire you have bought complies to 2006 95 EC 2004 108 EC and 2011 65 EU European Directives The l...

Page 6: ...tor to a mains protected by a suitable electric fuse according to the instructions supplied by the manufacturer of the lamps in use FOCUS AND REGULATION The luminaire should be at the minimum distance...

Page 7: ...COM 50 F Type Code W lm K t h V CP 85 5000 G 38 135000 3200 500 230 LAMPADE LAMPS DIMENSIONI E PESI DIMENSIONS AND WEIGHTS Kg 22 7...

Page 8: ...Spotlight s r l Via Sardegna 3 20098 S Giuliano Milanese Milano Italy Tel 39 02 98830 1 Fax 39 02 98830 22 E mail info spotlight it www spotlight it COM 50 F...

Reviews: