background image

Contents

Inspection

.

Description of the appearance

Features

Safety instructions

Lamp Installation

Rigging

Linking

,QVW

UXFW

LRQ

IRU

J RER

UHSO

DFHP HQW

DMX Channel Chart

Control Board

Maintenance

Replacing the Fuse

Appendix A  

Product Specifications

Connection with the mains

1

2

3

4

5

6

7

7

8

9

14

15

16

16

17

Summary of Contents for xp 575

Page 1: ...CAUTION ...

Page 2: ...ures Safety instructions Lamp Installation Rigging Linking QVW U XFW L RQ IRU JRER U HSO DFHP HQW DMX Channel Chart Control Board Maintenance Replacing the Fuse Appendix A Product Specifications Connection with the mains 1 2 3 4 5 6 7 7 8 9 14 15 16 16 17 ...

Page 3: ...eating moving colors as beautiful as the rainbow 10 000K and 6500K Temperature correction filter 3200K temperature correction filter IRIS linear adjustment Remote controlled focus Remote controlled lamp switch ON OFF Solid square base is convenient set on the TRUSS or directly stand on the ground or stage for uses Systematic modular construction design has all inner function wheels and PCBs modula...

Page 4: ...Description of the appearance Filter 2 ...

Page 5: ...e or loss caused by transportation Contact your PROLIGHTS dealer to assure your right by telephone or facsimile immediately if damage has occurred or if something is missing Packing List A XP SPOT 575 Moving Head B Operating Manual C D GOBO E Lamps Optional Bracket 3 ...

Page 6: ...ng to qualified technicians only Lamp and components become hot during operation Allow time to cool before handling Keep flammable material at least one meter away from unit Do not operate in wet conditions or near liquids Keep air vents clear to avoid overheating Lamp produces hazardous UV light Do not look directly at lamp when lit Replace any blown or damaged fuses only with those of identical ...

Page 7: ...e shutter cover with appropriate tool Wear the gloves and extract the lamp from the package loosen the screws on both sides of the lamp then slide the lamp paralleled into the lamp socket Adjust the round point of the lamp upward See Figure and fasten the screws snugly Reverse the above mentioned processes for the complete installation 5 WARNING Remove the power cord before installing the lamp ...

Page 8: ...of various venues Mount two attached brackets a on the bottom See Figure and collocate the appropriate clamps b to rig with trusses Must use the safety ropes that can hold the ten times as heavy as the fixture through the eye bolts c on the bottom of the base and trusses then join the safety ropes with screw on carabines d Rigging 6 ...

Page 9: ... DIP SWITCH 3 of last fixture to ON position for terminal confirmation 1 2 3 1 2 3 1 Ground 2 Signal 3 Signal 1 Ground 2 Signal 3 Signal 0 RXW SXW 5 P RXQ W L Q J VRFN HW 0 L Q SXW 5 P RXQ W L Q J SO XJ Connection with the mains Connect the device to the mains with the power plug The occupation of the connection cables is as follows Cable Pin International Brown Live L Blue Neutral N Yellow Green ...

Page 10: ...op cover Refer to the steps of lamp installation and loosen the screws with appropriate tools then extract A See the figures below 4 Insert the new GOBO and the spring ring Press the spring ring tight with the appropriate tools in order to keep GOBO compact put A back and screw up the top cover Fixed GOBO wheel The instructions are the same as changing the rotating GOBO only winkle the spring ring...

Page 11: ...ast max 7 flashes second Channel 2 Shutter Strobe Open white Steel Blue Orange Green Blue Bright Blue Bright Pink Red Deep Blue Yellow Dark Pink Moss Green Light Blue Color wheel rotation slow to fast 13 27 41 55 69 83 97 111 125 139 153 167 255 0 14 28 42 56 70 84 98 112 126 140 154 168 Channel 3 Color wheel 1 Function of the control channels 16 bit protocol 9 ...

Page 12: ... 13 27 41 55 69 83 97 111 125 139 153 167 255 0 14 28 42 56 70 84 98 112 126 140 154 168 Yellow Yellow Steel Blue Green Channel 4 Color wheel 2 Channel 5 Fixed gobo wheel Channel 6 Rotating gobo wheel Channel 7 Indexing Rotating gobo rotation Rotating gobo angle zero to 360 degrees adjustment from Forwards gobo rotation from fast to slow Backwards gobo rotation from slow to fast 127 191 255 0 128 ...

Page 13: ...sm static 1 7 132 253 255 0 2 8 133 254 Channel 9 Iris Closed Min Diameter to max diameter Iris in from slow to fast Iris out from fast to slow Open 159 207 253 255 0 1 160 208 Iris in Iris out Channel 10 Focus Focus adjustment from far to near 255 0 Channel 11 Pan regulation 253 254 254 255 The head of the unit is allowed to turn horizontally from zero to 570 degrees ...

Page 14: ...ter Standby 47 95 159 207 255 0 48 96 160 208 Channel 12 Tilt regulation Channel 13 Pan fine tune Channel 14 Tilt fine tune 12 The head of the unit is allowed to turn vertically from zero to 270 degrees While rotating horizontally the head is allowed to be fine tuned from zero to 2 2 degree While rotating vertically the head is allowed to be fine tuned from zero to 1 degree ...

Page 15: ...control channels 8 bit protocol DMX Channel Function 1 DIMMER 2 SHUT 3 COLOR 1 4 COLOR 2 5 GOBO 1 6 GOBO 2 7 GOBO 2 ROTATE 8 PRISM AND ROTATE 9 IRIS 10 FOCUS 11 PAN COARSE 12 TILT COARSE 13 AUTO RESET 14 LAMP ON OFF 13 ...

Page 16: ...Control Board 14 ...

Page 17: ...ixture should be cleaned at least half yearly using a vacuum cleaner or an air jet Caution Be careful not to damage the interior mechanical structures or circuits when using the air jet To ensure a proper function and smooth rotation of the gobo wheel we recommend lubrication in six month intervals Caution Avoid the damage of interior structures when fixtures rotated do not use excess lubrication ...

Page 18: ...ff position before replacing the fuse Replace the fuse as follows Step 1 Unscrew the screw of the fuse holder on the housing counterclockwise with appropriate tools Step 2 Remove the broken fuse and then replace the new fuse Step 3 Reinsert and tighten the screw on the fuse holder Step 4 Turn the power on for test Please contact with the dealer if the fixture still cannot work or the fuse Appendix...

Page 19: ...C10 4 Approved models Philips MSI 575 HR 1000 hr 6000K Philips MSI 575 2 1000 hr 6500K Control Automatic and DMX remote on off O HFW U RP HFKDQ L FDO HIIHFW V Color wheel 1 11 dichroic colors white Color wheel 2 11 dichroic colors white Fixed gobo wheel 9 replaceable gobos white Rotating gobo wheel 6 replaceable gobos white Gobo rotation adjustable speed and position direction Dimmer 0 100 linear ...

Reviews: