21
21
EN
• Use the massager only on soft tissue. DO NOT use it on the head or other bony areas.
• Irrespective of the vibration speed and setting of the device, slight bruising can occur, since the intensity
depends largely on the pressure of the user and the physical sensitivity of the user.
• Check the areas of the body that you treat regularly and stop the massage immediately at the first sign of
pain or discomfort.
• For use on the skin or on dry and clean clothing.
• When used over clothing, we recommend light things (sports clothing, form-fitting, leggings, etc.).
• Keep hair, fingers, and other parts of the body away from the massager that could become caught or
crushed.
WARNINGS FOR USE
10.
For indoor use only.
11.
Repairs of all kinds should only be carried out by specialist personnel.
Manufacturer’s name or trade mark, trade
register number and address
Fitwell International CO., LTD
16, Lane 92, SEC2, Sanjiau RD., Tiengzhong,
Changhua, Taiwan, 52044
Model Identifier
SK22G-0500200
Measured
value
Measuring
tolerance
Unit
Input Voltage
100-240V
+/- 1 %
V
Input AC Frequency
50-60Hz
+/- 1 %
Hz
Output Voltage
5.0
< 2 %
V
Output Current
2.0
/
A
Output Power
10.0
< 0.1
W
Average active efficiency
82.98
+/- 2 %
%
Efficiency at light load (10%)
--
+/- 1 %
%
No-load power consumption
0.068
< 0.1
W
Technical Data of the AC Adapter