background image

10

   

   

   

This   

is a Gasoline Powered Invertor Generator

   that   offers   clean   power   for   

electronics. 

1

ENGINE SWITCH 

The engine switch controls the ignition system. 

To Start generator, turn POWER  switch ON. Then the 
engine can be started by sliding Choke lever to CHOKE  
then pull Recoil. Allow engine to run for a few seconds 
then slide the Choke Lever to OFF. 

To Stop generator, press ignition circuit to STOP. The engine will not run. 

2

ECONOMY CONTROL SWITCH 

When the economy control switch is turned “ON”, the economy control unit controls 
the engine speed according to the connected load. The results are better fuel 
connection and less noise. (Turn OFF when using less voltage.) 

3

LOW OIL ALERT SENSOR 

When the oil level falls below the acceptable level, the engine stops automatically. 
Unless you refill with oil, the engine will not start again. 

4) OVERLOAD INDICATOR LIGHT 

The overload indicator light comes on when an overload of a connected electrical 
device is detected, the inverter unit overheats, or the AC output voltage rises. The 
electronic breaker will then activate, stopping power to the generation in order to 
protect the generator and any connected electric devices. The output pilot light will 
flicker GREEN, the overload indicator light will turn RED, & the engine will stop.  

 

(a)  Turn off any connected electric devices and stop the engine 

(b)  Reduce the total wattage of connected electric. 

(c)  Check for blockages in the cooling air inlet and the control unit & restart engine. 

l

  The generator AC output automatically resets when the engine is stopped and 

then restarted.  The overload indicator light may come on for a few seconds at 

Summary of Contents for GEN1000i

Page 1: ...ON ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you experience a problem have questions or need parts for this product call Customer Service at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRA...

Page 2: ...eceipt totherepairfacility recommendedbytheCustomerServiceRepresentative Thewarrantydoesnotextendtogenerators damagedoraffectedbyfuelcontamination accidents neglect misuse unauthorizedalterations useinan applicationforwhichtheproductwasnotdesignedandanyothermodificationsorabuse 1 YEAR LIMITED WARRANTY 30DayLimitedWarrantyforCommercialandRentalPurpose Generatorsarewarrantedtobefreefrom defectsinmat...

Page 3: ...s may apply if this generator will be used at a construction site IMPORTANT SAFETY INSTRUCTIONS STOP Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and or on this generator call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time Carbon Monoxide Gas When in operation the exhaust from this generator contains poisonous carbon m...

Page 4: ...ways shut down this generator before refueling Refuel in a well ventilated area Keep heat sparks and flame away while refueling and away from the location where gasoline is stored Never refuel indoors where gasoline fumes may reach flames and or sparks Allow this generator to cool for at least 2 minutes before removing the fuel tank cap Loosen the cap slowly to relieve pressure in the fuel tank Av...

Page 5: ...enerator either directly or with an extension cord NEVER connect a building electrical system to this generator without a qualified electrician Doing so voids your warranty Such connections must isolate generator power from utility power and comply with local electrical laws and codes Failure to comply can create a back feed into utility lines creating an electrocution hazard which may result in s...

Page 6: ...erator denoting hot surfaces Allow this generator to cool for several minutes after use before touching the engine muffler or other areas that are hot during operation and before storing indoors Hot exhaust may ignite some materials Keep flammable materials away from this generator Keep at least several feet of clearance on all sides of this generator during operation Do not enclose this generator...

Page 7: ...ttage capacity of this generator Do not turn on electrical devices until after they are connected to this generator Turn off all connected electrical devices before stopping this generator Usage Prolonged exposure to high noise levels can be hazardous to hearing Always wear ANSI approved hearing protection when operating or working around the generator when it is running Usage Avoid the use of ext...

Page 8: ...Usage Avoid the use of extension cords if possible If you choose to use them be sure they are sized adequately to handle the flow of electricity An undersized cord can overheat short out and cause a fire ...

Page 9: ...udeUse Thisgeneratorisnotrecommended forhighaltitudeuseabove3 000feet DESCRIPTION 1 Economycontrolswitch 2 Engineswitch 3 Fueltank 4 Sparkplug 5 Muffler 6 Carryinghandle 7 Chokelever 8 ACpilotlight 9 Overloadindicatorlight 10 Oilwarninglight 11 Ground earth terminal 12 DCprotector 13 DCreceptacle 14 ACreceptacle 16 Fuelfilter 17 Fueltankcap 18 Fuelpump 19 Recoilstarter 20 Fuelcock 21 Oilfillercap ...

Page 10: ...ls below the acceptable level the engine stops automatically Unless you refill with oil the engine will not start again 4 OVERLOAD INDICATOR LIGHT The overload indicator light comes on when an overload of a connected electrical device is detected the inverter unit overheats or the AC output voltage rises The electronic breaker will then activate stopping power to the generation in order to protect...

Page 11: ...urn ON when getting ready to start the generator Turn OFF when finished using the generator CHECK ENGINE FUEL l Make sure there is sufficient fuel in the tank l If fuel is low refill with unleaded automotive gasoline l Be sure to use the fuel filter screen on the fuel filter neck l Recommended fuel Unleaded gasoline l Fuel tank capacity 0 5 Gallon l Do not refill tank while engine is running or ho...

Page 12: ... OPERATION STARTING THE ENGINE l Before starting the engine do not connect electric apparatus 1 Turn the fuel cock lever to the ON position 2 Turn the fuel tank cap air vent knob clockwise to the OPEN position Turn the engine switch to the ON or RUN position 3 Turn the choke lever to the Close Choke position 4 PUMP the PRIMER button until the glass bowl is full 5 Pull the recoil starter handle slo...

Page 13: ... socket load current is within socket rated current l The economy control switch must be turned to OFF when using electric devices that require a large starting current such as a compressor or a submergible pump DC APPLICATION This usage is applicable to 12V battery charging Be sure the economy control switch is turned off while charging the battery STOPPING THE ENGINE 1 Turnoffthepowerswitchofthe...

Page 14: ...kconditionadjustgapandclean Replaceifnecessary l EngineOil Checkoillevel l Replace l l Oilfilter Cleanoilfilter l AirFilter Clean Replaceifnecessary l FuelFilter Cleanfuelcockfilter Replaceif necessary l Choke Checkchokeoperation l Valve Clearance Checkandadjustwhenengineiscold l FuelLine Checkfuelhoseforcrackordamage Replaceifnecessary l Exhaust System Checkforleakage Retightenor replacegasketifn...

Page 15: ...hepilotlightcomeson l ENGINE OIL REPLACEMENT 1 Place the machine on a level surface and warm up the engine for several minutes Then stop the engine and turn the fuel cock knob to OFF Turn the fuel tank cap air vent knob clockwise 2 Loosen the screw and remove the cover 3 Remove the oil filler cap 4 Place an oil pan under the engine Tilt the generator to drain the oil completely 5 Replace the gener...

Page 16: ...ut engines Keep the element always clean 1 Remove the cover 2 Remove the air filter cover and element 3 Wash the element in solvent and dry 4 Oil the element and squeeze out excess oil The element should be wet but not dripping 5 Insert the element into the air filter 6 Install the cover The engine should never run without the Filter excessive piston and or cylinder wear may result CLEANING AND AD...

Page 17: ...engine and muffler while they are still hot with any part of your body or clothing during inspection or repair 1 Remove the cover 2 Remove the muffler screen 3 Use the flathead screw driver to pry the spark arrester out from the muffler 4 Remove the carbon deposits on the muffler screen and spark arrester using a wire brush 5 Install the muffler screen 6 Install the cover TROUBLE SHOOTING Engine w...

Page 18: ...aulty ignition system Consult dealer Compression insufficient l Worn out piston and cylinder Consult dealer Generator won t produce power Safety device AC to OFF Stop the engine then restart Safety device DC to OFF Press to reset the DC protector STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration 1 DRAIN THE FUEL 1 Remove the fuel tank ...

Page 19: ...ression 4 Stop pulling 5 Clean exterior of the generator and apply a rust inhibitor 6 Store the generator in a dry well ventilated place with the cover place over it 7 The generator must remain in a vertical position SPECIFICATION MODEL GEN1000i GENERATOR Type InvertorGenerator ACVoltage 60Hz 120V Max Output 1 00kVA RatedOutput 0 80kVA PowerFactor 1 0 DCOutput 12V 4 0A ENGINE Model XY139F 6 Type A...

Page 20: ...30 LubricatingoilCapacity 10ounce StartingSystem RecoilStarter Ignitionsystem C D I SparkPlug Type CMR6A TORCH DIMENSION Netdimension L W H 395 209 355 Overalldimension L W H 425 230 380 NetWeight 9 2Kg GrossWeight 11 4Kg l Specifications subject to change without prior notice High Altitude Use This generator is not recommended for high altitude use above 3 000 feet ...

Page 21: ...or by loosening the drain screw 2 ENGINE Remove the spark plug pour in about one tablespoon of SAE 10W30 motor oil into the spark plug hole and reinstall the spark plug Use the recoil starter to turn the engine over several times with ignition off Pull the recoil starter until you feel compression Stop pulling Clean exterior of the generator and apply a rust inhibitor Store the generator in a dry ...

Page 22: ...22 The generator must remain in a vertical position WIRINGDIAGRAM ...

Page 23: ...23 ...

Page 24: ...24 ...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ...28 ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...31 201701 ...

Reviews: