18
l
Fuel in tank
…
.Fuel tank cap air vent knob to “
OPEN
”, fuel cock knob to “
OPEN
”.
l
Clogged fuel line
…
.Clean fuel line.
l
Clogged carburetor
…
.Clean carburetor.
Engine oil system
Insufficient
l
Oil level is low
…
.Add engine oil.
Electrical systems
Poor spark
l
Spark plug dirty with carbon or wet
…
.Remove carbon or wipe spark plug dry.
l
Faulty ignition system
…
.Consult dealer.
Compression insufficient
l
Worn out piston and cylinder
…
.Consult dealer.
Generator won’t produce power
Safety device (AC) to “OFF”
…
Stop the engine, then restart.
Safety device (DC) to “OFF”
…
Press to reset the DC protector
STORAGE
Long term storage of your machine will require some preventive procedures to
guard against deterioration.
1
)
DRAIN THE FUEL
1. Remove the fuel tank cap, drain the fuel from the fuel tank
2. Remove the cover, drain fuel from the carburetor by loosening the drain screw.
2
)
ENGINE
Summary of Contents for GEN1000i