SPORTSBEAMS LED 800 User Manual Download Page 6

SPORTSBEAMS LIGHTING, INC.

4.

1.888.905.6680 | WWW.SPORTSBEAMS.COM

INSTALLATION & AIMING

ATTACHING FIXTURES

HARDWARE PROVIDED

The Sportsbeams Chromabeams LED 800 Fixture can be mounted on top of a mounting structure or underneath. The 

mounting structure may be a light pole cross arm, an indoor catwalk bracket, or other structural component that will 

hold the fixture firmly in place and ensure enough clearance to adjust fixture for the correct beam angle. This fixture 

is designed to be mounted and aimed in accordance to a proper light design to ensure consistant light coverage.

It is the responsibility of the installer to verify that all proposed mounting structures including poles, cross arms, catwalk brackets, and 
other mounting structures are certified to support the weight of the fixture, withstand wind loads, and meet all other applicable codes and 
regulations. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.

Do not suspend any fixture by electrical or control wires, as these will not support the weight of the fixture, resulting in the potential for the 
fixture to fall and cause damage or injury. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY 
DAMAGE.

An impact driver may be used on mounting hardware while the power is off, but vibration caused by power tools may 
damage the fixture. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO FIXTURE INTERNAL DAMAGE AND FAILURE. 

Fixtures mount to our custom poles or provided adapter 
plates via four M10 bolts.

Each fixture will contain the following hardware:

QTY

DESCRIPTION

4

M10 COURSE THREAD BOLTS

4

M10 FLAT WASHER

4

M10 SPRING LOCK WASHER

4

M10 HEX BOLT

PICTURE

4 x M10 bolts fix the base 

plate to the cross arm

Summary of Contents for LED 800

Page 1: ...SPORTSBEAMS LED 800 USER MANUAL SPORTSBEAMS LIGHTING INC v 1 1 1 888 905 6680 WWW SPORTSBEAMS COM...

Page 2: ...dard Wiring Diagrams Site Power Distribution Power DIstribution Control Box Incoming Outgoing Connections Indoor Control Topography Outdoor Control Topography Control System Overview EMERGENCY CIRCUIT...

Page 3: ...nce with many of the the following safety directives SUITABLE FOR WET LOCATIONS CONVIENT AUX EMPLACEMENTS MOUILL S WARNING RISK OF FIRE OR ELECTRIC SHOCK Please visit www sportsbeams com for a complet...

Page 4: ...uch as hardhats safety glasses reflective vests electrical safety gloves fall protection equipment and safety toe boots during the installation operation and maintenance of the luminaire FAILURE TO FO...

Page 5: ...pecifically designed and engineered by Sportsbeams will VOID THE WARRANTY on this fixture Failure to wire your fixture properly as suggested below can cause permanent damage to the fixture and or can...

Page 6: ...upport the weight of the fixture withstand wind loads and meet all other applicable codes and regulations FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE Do not suspe...

Page 7: ...ing diagram will give precise aiming numbers for every single fixture VERTICAL AIMING Lift the fixture until the vertical dial matches the number on the provided aiming diagram and lock the bolts HORI...

Page 8: ...intakes around the top of the light and nothing is blocking the output of air from the back of the light this fixture can be freely mounted at any angle SPORTSBEAMS LIGHTING INC 6 1 888 905 6680 WWW...

Page 9: ...Sportsbeams Pole length network cable provided by Sportsbeams Power Distribu on Control Box A ach the wiring harness to the AC whip from the power supply Moun ng yoke style may vary Plug the waterpro...

Page 10: ...with 14AWG annealed stranded bare copper per ASTM B 174 with a minimum temperature range of 40 C to 90 C Our cable is water resistant UV rated sunlight resistant UL listed and CSA certified for indoo...

Page 11: ...OWER SUPPLY INTELLIBEAM LIGHT SERVER INDIVIDUAL POWER BRANCHES HOT NEUTRAL GROUND RED BLACK GROUND RED BLACK DATA UP TO 24 ROUTER SWITCH CPU INTELLIBEAM CONTROL BOARD INTERNET INTRANET ONSITE POWER BO...

Page 12: ...ould be delivered to the power distribution box mounted on a pole or at a specific location Each fixture is then wired to individual breakers inside power distribution control box provided by Sportsbe...

Page 13: ...r Control Breaker Surge Protection Device Breakers Cable Restraint Fiber Splice Tray Contactor Mast Cabinet Control Breaker Connecting Terminal DC24V Power Supply DC Power Conversion Relay Connecting...

Page 14: ...TSBEAMS COM INSTALLATION AIMING Fiber Outgoing Fiber Power to Fixtures Emergency Switched 480V to 208V AC Power Incoming Connections Outgoing Connections Contractor to wire incoming power fiber ethern...

Page 15: ...GY SPORTSBEAMS LIGHTING INC 13 1 888 905 6680 WWW SPORTSBEAMS COM INSTALLATION AIMING CONTROL BOX DC POWER POWER DISTRIBUTION BOXES NETWORK BOXES 10 BUTTON DMX CONTROL BUTTON 4 WIRE OR ETHERNET CABLE...

Page 16: ...COM INSTALLATION AIMING CONTROL BOX DC POWER POWER DISTRIBUTION BOXES POWER DISTRIBUTION BOX 120V 208V 240V 277V 480V 120V 208V 240V 277V 480V TO INDIVIDUAL POWER SUPPLIES FIBER OR ETHERNET 10 BUTTON...

Page 17: ...his box sits indoors press room ticket booth etc 110V power is attached to the top breaker The routers and DC transformer are mounted on DIN rails along with our Facility DMX computer 4 FIXTURE RECEIV...

Page 18: ...CUIT CONTROL BOX TO INDIVIDUAL FIXTURES EMERGENCY CIRCUIT POWER NORMAL POWER BACKUP GENERATOR POWER EMERGENCY LIGHTING SCENARIO 1 In the event that main power is lost control signals stop but the ALCR...

Page 19: ...om the luminaire housing Wipe the optical lenses with a clean dry cotton cloth to remove dust and other contami nants A non abrasive polycarbonate cleanser may be used periodically Turn off power befo...

Page 20: ...k wiring connections Refer to minimum fuse ratings SYMPTOM No light output Fuse blows or circuit breaker trips POSSIBLE CAUSE Power is off Bad wire connection Control signal set to 0 Crossed wires or...

Page 21: ...d Glass Transparent Diffusive 36 lbs EPA front 1 93 ft2 Light Engine CCT CRI LUMINAIRE EFFICIENCY DELIVERED LUMENS FLICKER DIMMING LUMEN MAINTENANCE LED DIMMING RESOLUTION 2700k to 6300k option 70 80...

Page 22: ...nterference that may cause unde sired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 1 888 9...