Troubleshooting
Model: T6
45
Malfunction: Incline will not operate upward or downward.
Circumstance: Press incline keys; there is no incline action.
Possible causes: 1. Zero switch has malfunctioned.
2. Cables are not connected.
3. Incline motor is not operating.
Troubleshooting: 1. Inspect drive board cable connections.
2. Inspect zero switch calibration.
3. Inspect incline signal indicators on the drive board
and measure incline output voltage.
4. Listen for the sound of incline gear grinding.
5. Feel the incline motor. Is it hot? If it is hot,
the drive board could be malfunctioning.
Replace the drive board.
3-6-1
SAC Drive Board
Display board
Zero
SW
AC-Incline
Unit
Incline gear box
Zero switch
Incline Zero switch
Drive
board LED
0%
on
lit
1-15%
off
No lit
Incline motor voltage
Direction
Incline cable
Incline voltage
up
White - black
110v or 220v
down
White - Red
110v or 220v