22
| SPONGE-JET RASP RX3 USER MANUAL
1.
Release
Deadman Handle
and
depressurize unit.
2.
Close
Main Air Ball Valve.
3.
Press in
Emergency Stop Button
.
Auger stops rotating during normal operation
1
1
Remove
Clean Out Trap.
Rotate
Manual Rotation Knob
clockwise and counter-clockwise
until obstruction falls out.
Auger
should move smoothly.
Replace
Clean Out Trap.
If obstruction cannot be cleared
through
Clean Out Trap
:
Remove
Manual Rotation Knob
by pressing it into the
Auger Chain
Guard
and rotating clockwise.
Remove
Auger Chain Guard
.
Remove (4) outside screws, pull
Auger
from unit and remove
obstruction.
Reassemble
Auger
; replace (4)
outside screws, and test for smooth
rotation. Re-install
Auger Chain
Guard.
2
2
3