SPONGE-JET RASP RX3 USER MANUAL |
15
Press
Deadman Handle
down
and wait 5 to 10 seconds for
Sponge Media to flow.
Adjust
Blast Pressure
and
Media
Feed Pressure
to desired levels.
Note:
to make adjustment to desired
levels, pull knob, rotate to desired
setting, then push in to lock.
Confirm
Manual Rotation Knob
is
rotating.
Prepare surface to desired condition.
Nozzle Size
Sponge Media Recycles
Working Mix
1-3
4-6
7-12
bar psi
bar psi
bar psi
#7 10mm (7/16in)
2.0 30
1.5 20
0.7 10
#8 12mm (1/2in)
2.8 40
2.0 30
1.5 20
Typical Media Feed Pressures