9
4.
To charge the battery, only use the original mains charger included in the box. Use of
other chargers may damage the battery or may cause serious injury.
Storing of Splosh #2
Your Splosh #2 should be stored in such a way to protect it from freezing. Do not store this
unit outdoors or on an area where temperatures will fall below 0°C (32°F). This can cause
extensive damage to this unit and void the warranty. Before storing, follow the shutting down
instructions.
Drain water from unit:
1.
Turn off at the switch, squeeze the nozzle lever to release pressure. Remove
nozzle and squeeze nozzle to drain water from nozzle. Empty water from tank.
Turn the unit on and run for approximately 30 seconds without nozzle.
2.
Detach high-pressure hose. Elevate one end and allow water to drain from hose.
3.
Remove and place hose, nozzle and power cord in mesh storage compartments.
4.
If unit must be stored in freezing conditions, or will be stored for more the 30 days,
a pump winteriser / protector or a non-toxic RV anti-freeze can be used to prevent
freezing and reduce mineral deposits.
Add anti-freeze as follows:
1.
Pour approximately 3 litres (1/2 gallon) of RV anti-freeze into tank.
2.
Connect high-pressure hose, nozzle, and power cord.
3.
Turn the unit on, squeeze lever until a steady stream of RV anti-freeze in present.
4.
Turn the unit off. Squeeze nozzle lever to release pressure.
5.
Remove and place the hose, nozzle and power cord in mesh storage
compartments.
Using unit after storing with anti-freeze:
1.
Drain RV anti-freeze. (follow steps 1 and 2 from Drain water from system)
2.
Run 1 tank of fresh water through system before using and ensure all anti-freeze
is purged from system.
WARNING: USE ONLY RV ANTIFREEZE. ANY OTHER ANTI-FREEZE IS CORROSIVE
AND CAN DAMAGE PUMP AND VOID WARRANTY.
Summary of Contents for Splosh 2