Installation and Reference Manual
System Operation
Installation and Reference Manual v3.2/0410/6
51
Default Dial Plan entries
The PCS 10 is supplied with 10 pre-programmed buttons which dial specific dial plan entries. Therefore
the User assigned to the PCS 10 must be configured with a Dial Plan containing these default dial plan
entries. For details on working with Dial Plans please refer to page 114 and, within this section, details on
using the default dial plan entries from page 121.
Connecting a PCS 505 or PCS 5
When connecting a PCS 505 or PCS 5 to an analogue port the following should be considered:
Caller Display Type
The Default Caller Display Type for an analogue port uses the Caller Display Type required for use with the
PCS 505 or PCS 5 however if the handset is to support the Message Waiting light the Lamp Caller Display
Type should be used. For details on how to configure an Analogue Extension port please refer to
page 77.
Default Dial Plan entries
The PCS 505 and PCS 5 are supplied with a System Feature Guide displayed on the handset detailing the
use of specific dial plan entries. Therefore if the User is going to utilize these dial plan entries the User
must be configured with a Dial Plan containing these entries. For details on working with Dial Plans
please refer to page 114 and, within this section, details on using the default dial plan entries from
page 121.
Connecting a PCS IP Phone
Power over Ethernet considerations
Power to the PCS 580G, PCS 570G/570, PCS 560, PCS 410/400 and PCS 100 is provided by Power over
Ethernet (PoE). This can be supplied by a third party PoE switch or by the following methods:
•
PCS 580/570/560 – via one of the PoE LAN ports on a Call Server or Phone Module, or via a Single
Terminal Ethernet Power Supply (STEPS)
•
PCS 410/100 - via one of the PoE LAN ports on a Call server or Phone Module, or via a Single Terminal
Ethernet Power Supply (STEPS)
•
PCS 400 - via one of the PoE LAN ports on a Call server or Phone Module, or via a Single Terminal
Ethernet Power Supply (STEPS). The PCS 400 can also obtain power via a PCS PSU when it is not
practical to use PoE. Please note that if a PCS 400 is connected to a PoE LAN port on a 5100 or 5108
Call Server the PCMCIA card cannot be used.
Please note that if a STEPS is used with a PCS 580G or PCS 570G the LAN port (port 1) will not run at 1G.
PoE LAN ports are provided as follows:
5100 Call Server, 5108 Call Server and 5300 Phone Module – provides 4 x PoE LAN ports supporting the
following combinations:
1 x PCS 580G or
1 x 410/400 or
up to 2 x PCS 570G/570 or
up to 4 x PCS 100/PCS 560 or
up to 1 x PCS 570 and 2 x PCS 100/PCS 560