1.  OBSERVE SAFETY INSTRUCTIONS 

  Make  sure  you  have  read  and  understood  the  whole  instruction 

manual before installing, operating or carrying out any maintenance 
on this unit. 

  Warnings  and  data  plates  on  the  unit  provide  important  directions 

and information on the safe use of the unit. 

  In addition to these operating and safety instructions please make 

sure that all accident prevention regulations applicable in the country 
of use are followed. 

  In addition to these operating and safety instructions any standards relating to the installation and 

operation of high pressure cleaners applicable in your country must be strictly followed. 

  This unit is not intended for use by children. Children must always be supervised when in the vicinity 

and ensure that they DO NOT play with the unit. Further, it is not intended for use by persons with 
reduced physical, sensory or mental capabilities, or lack of experience or knowledge. It must only 
be operated by persons instructed in its use who have been especially authorized to do so. 

  DO NOT operate the unit without appropriate personal protective equipment (PPE). 

 

2.  ELECTRICAL CONNECTION 

  The voltage, hertz rating and number of phases on the serial label 

must correspond to that of the electrical mains outlet. 

  Only connect the unit to electrical installation made by 

certified 

electrician and comply with IEC 60364-1.

 

  It is recommended that the electrical supply to this unit should 

include either a residual current device that will interrupt the 
supply if the leakage current to earth 

exceeds 30mA for 30 ms

 or 

a device that will prove the earth circuit. 

  Switching on the unit may cause voltage fluctuations. Voltage 

fluctuations should not occur if the impedance of the transfer point 
is less than 0.15Ω. If in doubt contact your power supplier. 

  This Class 1 Appliance must only be connected to an earthed 

power supply fitted with an appropriately sized fuse. 

 

3.  POWER CORD 

  Make sure before every use that the power cord assembly is not 

damaged or cut. If it is DO NOT connect the unit, have it replaced 
by an electrician or authorized service technician. 

(Type Y 

attachment)

 

  DO NOT pull on the power cord in order to unplug the unit, 

remove the plug from the power outlet.

 

 

 

4.  FIRE PREVENTION 

  Under NO circumstance use flammable liquids, undiluted acids or 

solvents as a chemical as the spray produced would be highly 
flammable.

 

 

 
 
 

GENERAL SAFETY PRECAUTIONS 

 

 

 

 

 

 

 

30mA

 

 

 

 

 

 

Summary of Contents for 10-120C

Page 1: ...is instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer from...

Page 2: ...accordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the m...

Page 3: ...LECTRIC POWER 3 3 3 HP PUMP MODEL WW95 WW95 WW95 OIL TYPE 15W 40 15W 40 15W 40 OIL CAPACITY 0 3 0 3 0 3 L OTHER DETERGENT BOTTLE CAPACITY N A L VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRESSUR...

Page 4: ...t cautious Their meaning is listed next to them for your attention CAUTION Electric shock hazard Disconnect power before removing cover DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUT...

Page 5: ...H HIGH PRESSURE HOSE PRESSURE HIGH LOW LANCE HOLDER HANDLE PLUG SLD10 ONLY LANCE CHEMICAL HOSE HIGH PRESSURE WATER OUTLET CONNECTOR SERIAL LABEL REMOVE PANEL TO VIEW Always pay attention to the safety...

Page 6: ...ent PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that of the electrical mains outlet Only connect the unit to electrical installatio...

Page 7: ...unit s power cord 6 TRIP HAZARD Loose extension cords and power cables provide a potential trip hazard especially when they cross pathways Take safety measures like placing traffic cones along the co...

Page 8: ...er is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries o...

Page 9: ...parts that were not designed for use with this unit as this could cause damage to the unit Spitwater recommends the use of original accessories and spare parts available through Spitwater and its exte...

Page 10: ...in order to prevent it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or bel...

Page 11: ...hed Please note that incorrect voltage or insufficient power supply will cause immediate damage to the unit Note Any work needed on initial installation to connect the unit to the power supply must be...

Page 12: ...lease adaptor to the high pressure hose fitting Do not over tighten 11 ASSEMBLY OF HIGH PRESSURE HOSE WITH THE UNIT Connect the quick release high pressure hose to the outlet connector of the unit Hig...

Page 13: ...turn the water supply on Visually check for leaks and contact your Spitwater service agent if found Open the water supply and check for any leaks Water that has flowed through backflow preventer is co...

Page 14: ...the spray gun a few times to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of...

Page 15: ...e the detergent filter reach container bottom and it is fixed securely Only use a cleaning detergent approved by the manufacturer and do not use under any circumstance acid or corrosive products conta...

Page 16: ...it from the power supply 4 Release all trapped water pressure in the unit by pulling the trigger of the spray gun then engage the spray gun trigger lock Failure to follow this instruction will leave t...

Page 17: ...s that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater service...

Page 18: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Check pressure gauge to show working pressure as per Technical data sheet when the trigger is in ON position Check for...

Page 19: ...r units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingl...

Page 20: ...unit is on a flat surface Check the oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is...

Page 21: ...w water cut off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated th...

Reviews: