6
How to Wire This Ceiling Fan
WARNING
To avoid possible
fi
re or shock, be sure electricity is
turned off at the main fuse box before wiring.
(Figure 1)
Figure 1
MAIN FUSE BOX
Figure 2
Figure 3
Ceiling fans must be installed by a licensed electrician.
▲
WARNING
Check to see that all connections are tight, including
earth, and that no bare wire is visible at the wire
connectors, except for the earth wire. Do not operate
fan until the blades are in place. Noise and motor damage
could result.
1.
Securely connect the green/yellow earth wires from the
hanger ball and the hanger bracket and the supply
green/yellow earth wire to the terminal block as shown in
Figure 2.
2.
Securely connect the blue fan motor wire and the black
supply neutral to the “N” terminal of the connector block
as shown in Figure 2.
3.
Securely connect the brown fan motor wire and the red
(Active) supply wire to the “L” terminal of the connector
block as shown in Figure 2. After connections have been
made, carefully push leads into the recess making sure
there is separation between connectors.
INSTALLATION NOTE:
If light fixture is NOT required,
terminate the orange light wire. If light fixture is required,
refer to documentation supplied with lighting fixture for
further instruction.
Installing Wall Control (Rotary) Switch
1.
With electrical power still disconnected, install fan
switch control wiring to desired location on wall.
2.
Ensure wiring connections are as shown in Fig 2. The
Active (Red) supply wire must be connected
to terminal "C" on the rotary switch. Return switched wire
to ceiling fan to be conected from terminal ˝1˝ on the rotary
switch to ˝L˝ terminal on the connector block.
3.
Fit the wall control (rotary) switch to a face plate (not
supplied) and attach to wall.
INSTALLATION NOTE:
The “O” and the small corner
cut-out on the front of the switch mechanism must be at
the top and top left respectively (See Figure 3).
IMPORTANT:
Fan installation must be completed,
including the installation of the fan blades, before testing
of the controls.
4.
Restore electrical power to the ceiling fan by turning
the electricity on at the main fuse box.
5.
Check the operation of the fan by rotating the control
through the four positions marked 0 - III
(“0” position is OFF) (Figure 4).
6.
All fans are shipped from the factory with the reverse
switch positioned to circulate air downward.
If airflow is desired in opposite direction, turn your fan
OFF and wait for the blades to stop turning,
then slide the reversing switch to the opposite position,
and turn fan on again.
Terminal Block
(on Hanger Bracket)
Supply Cable
Grn/Yel Wire
(Earth) from Hanger Bracket
Grn/Yel Wire
(Earth) from Fan
Blue Wire
(Neutral)
Orange Wire
(Light Active)
Brown Wire
(Motor Active)
3
2
1
C
Capacitor
Red
Purple
Br
own
Rotary Switch
Red Wire
(Active)
Red Wire
(Active)
Black Wire
(Neutral)
Grn/Yel Wire
(Earth)
N
L1
L
Hanger Ball
Figure 4
= OFF = FAST = MED
= SLOW
Summary of Contents for MA6720 AU series