background image

 

© 2018 Spireon, Inc.

9

 / 

12

 

 

reception of reports, the device can be configured either in Normal or Ack’ed mode to 

send the reports. In the Normal mode the reports are simply sent “as is” with no 

acknowledgment from the server. In the Ack’ed mode every report sent is expected to 

be acknowledged by the server by sending back an ACK message back. If 

acknowledgement is not received within the specified timeout, the report is re-sent. If 

the report is not acknowledged after the specified number of attempts, it is queued. If 

acknowledgement is received after the report is queued (i.e. past timeout of the last 

attempt), it is ignored.   

 

Report is not considered “complete” until its acknowledgement is received. Thus, if 

report X is sent and report X+1 is triggered while waiting for acknowledgement of X, 

report X+1 will be queued until such acknowledgement is received and only then sent. 

The JG-LS will attempt to re-send queued report(s) every time a new report is 

triggered. If there is more than one report queued, the reports will attempt to be sent in 

the order of triggering and only once the report is acknowledged, the next report is 

attempted. This assures that reports are sent and received in order.   

 

Ack’ed mode assures that all reports are received, but adds overhead in time and 

data. Report that is not acknowledged is sent again and eventually will be queued and 

sent again. The number and frequency of re-tries is configurable via the Report 

Acknowledgement command. 

 
Event Report Format 

Reports are encoded as binary hex.   

 

 

Reset 

There are a number of resets available on the device. Soft reset only restarts the 

baseband on the device. Hard reset is caused by resetting the whole baseband 

module via a reset pin. There is also an option to reset the cellular and GPS 

sub-systemsonly. 

Context Preservation 

When a self-initiated reset is performed due to Network Watchdog or by the Reset 

command (modes 0,1), the context of the system is being preserved and is restored 

after the reset. The context includes all the periodic timers, the report queue, the 

odometer, etc. This allows to reset the unit as a troubleshooting or preventive 

measure without losing reports that are already in the queue or are pending on 

running timers. Note that the reset process may cause 1-2min of inaccuracy in the 

timers and should not be considered as very precise. 

Startup Banner 

After a reset a startup banner is printed through the UART only. 

Summary of Contents for JG-L

Page 1: ...Device September 18 2018 R1 2 Author Revision Changes Date Ewing 1 1 Initial version 2018 09 18 The information presented in this document is strictly confidential and contains trade secrets and other confidential information that are the exclusive property of Spireon Inc ...

Page 2: ...e Update 8 Power Modes 8 Report 8 Reset 9 Context Preservation 9 Startup Banner 9 Test Method 10 Hardware 10 Software Test 10 Mechanical Structure mm 11 FCC Statement 12 The information presented in this document is strictly confidential and contains trade secrets and other confidential information that are the exclusive property of Connected Holdings ...

Page 3: ... connection or through SMS messaging The JG L Spresents itself over these connections as an enhanced cellular modem with attached functional elements These elements include GPS location engine 2 General Purpose Bidirectional I O GPIO pins 1 Relay Output 1 Tamper 1 1 Wire Bus Interface 3 3V Power out for Peripheral Sensors Serial UART port Input voltages and Battery Voltage monitor Timers Watchdog ...

Page 4: ...via the solar panel or external power Hardware Design Basic Hardware Items Requirement Baseband Module Based on Quectel EC21 A baseband module Air Interface Support for LTE B12 B4 B2 WCDMA B2 B4 B5 Frequency B2 MHZ TX 1850 1910 RX 1930 1990 B4 MHZ TX 1710 1755 RX 2110 2155 B12 MHZ TX 699 716 RX 729 746 B5 MHZ TX 824 849 RX 869 894 Antenna integral antenna UIM requirement Support 3FF SIM interrupt ...

Page 5: ...ted in real time from the unit via the UART connection using special debug commands that are outside the scope of this document GPIO Two general purpose GPIO and two additional multiplexed IO s are presented to the external environment on the main connector They are capable of providing system interrupts to generate a report or drive logic levels to external devices These lines are 3 3V logic leve...

Page 6: ...start detection to wake the unit up from a sleep mode and driving behavior monitoring UART A UART port is provided for AT command and data interaction The UART can also serve to attach other accessories such as cargo sensor 1 Wire A 1 Wire interface is supported to attach external sensors such as temperature sensor etc Relay Driver A 500mA sink capable output pin is provided This pin is meant to d...

Page 7: ...30 to 85 C Storage Humidity 30 to 95 Operation 10 to 95 Storage Vehicle ISO Test ISO7637 2 2004 ISO7637 3 2007 ISO10605 2008 ISO16750 2 2010 FCC Certification FCC 47 CFR Part 15 Part 2 Part 22 Part 24 Part 27 Others Operator Requirement Industry Canada AT T optional ESD Requirement Contact Discharge 4KV Voltage Air Discharge 8KV Voltage Software Features Basic Software Items Requirement Network In...

Page 8: ...rs a report Those events include GPIO change Battery threshold Heartbeat Power up Accelerometer Tamper Any hardware or software reset will return the device to full power mode Report The JG LS captures data and forms a report record with that data A report is a data structure containing all of the sensory and other typically useful data on the device Reports are generated in response to specified ...

Page 9: ...the next report is attempted This assures that reports are sent and received in order Ack ed mode assures that all reports are received but adds overhead in time and data Report that is not acknowledged is sent again and eventually will be queued and sent again The number and frequency of re tries is configurable via the Report Acknowledgement command Event Report Format Reports are encoded as bin...

Page 10: ...dity Test RF Test RF Performance Test GPS Performance Test Antenna Performance Test Software Test Test Environment Construct Message Test environment 1 USB dongle and PC as message server 2 Send message to JG LS UDP Test environment 1 Connect dongle to PC and create dialup as ip server 2 JG LS create IP connection to server UART Test environment 1 Connect JG LS to pc with com serial cable 2 Open T...

Page 11: ... 2018 Spireon Inc 11 12 Mechanical Structure mm ...

Page 12: ...erienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received includin...

Reviews: