IM-P505-02-US
Issue 1
16
UTM20 Series Ultrasonic Transit-time Flowmeters
7.5 Installing a Meter with a Remote Transmitter and Fixed
Transducers
Locate the transmitter within the length of the transducer cables supplied or exchange the cable for
one of proper length.
See the dimensions section for enclosure and mounting dimension details. Allow enough room for
door swing, maintenance and conduit entrances.
Important
When routing wires to the transmitter, make sure the cables are not twisted, pinched or hanging loosely.
1.
Install the fixed transducers according to instructions in the transducer user manual.
2.
Attach the mounting bracket to a wall (with 4 customer-supplied #8 or M4 screws, see “Wall Mount
Bracket” in dimensions) or to a pipe (with mounting straps).
Fig. 9
Fig. 10
3.
Align the transmitter's bracket with the mounted bracket. Use a 4 mm hex tool to secure the 4
provided screws from the sides through the mating holes. See Figure 9.
4.
If necessary, you can rotate the mounting bracket in 90° increments to accommodate the final
orientation of the transmitter. From inside the enclosure, remove the 4 screws holding the bracket.
Rotate the bracket and replace the screws. See Figure 10.
Holes for Screws
for Wall Mounting
Holes for Screws
for Wall Mounting
Slots forStraps
for Pipe Mounting
Slots forStraps
for Pipe Mounting