background image

IM-P180-31 

CMGT Issue 11

6

2.1 Description

The Spirax Sarco BT6-B sanitary balanced pressure thermostatic steam trap is designed to remove 

condensate from clean and pure steam applications with minimal condensate retention. Applications 

include sterile steam barriers, block and bleed installations, mains drainage and CIP/SIP of vessels and 

reactors and process lines. Manufactured in 316L, the crevice free body design of the BT6-B incorporates 

a 15

°

 angled seat to ensure full drainability. 

The standard element is extremely sensitive to changes in condensate temperature and is designed to 

open with a minimum of sub-cooling, less than 2

 

°C from steam saturation temperature at pressures 

below 2.5 bar g for typical operating conditions. Exact operating performance may be affected by 

operating pressure, installation and ambient conditions. Each trap is individually packaged within an ISO 

CLASS 7 'clean' environment with protective end caps and sealed in a protective plastic bag.

Options:

-

Fixed bleed to ensure 'FAIL OPEN' operation.

-

Mechanical and electropolishing to 0.375 μm Ra (15 micro-inch Ra,ASME BPE SFV4).

-

For applications requiring closer to steam saturation temperatures, for example, critical SIP 

applications, please consult Spirax Sarco.

Standards

-

The BT6-B has been designed and built in general accordance with ASME BPE.

-

The unit also complies with the requirements of the Pressure Equipment Directive (PED).

The seal part is compliant with:

-

FDA CFR Title 21. Paragraph 177. 1550.  

-

USP Class VI Biological Reactivity Cytotoxicity Testing In-Vitro <87> & In-Vivo <88> extracted at 

121 °C for 1 hour.

-

ADI  Free  (Animal  Derived  Ingredients)  for  materials  used,  manufacturing  processes  involved  in 

producing the part.

Certification

This product is available with the following certification:

-

EN 10204 3.1 material certificates (pressure containing parts)

-

EN 10204 3.1 material certificates (wetted parts, including element fill) subject to additional cost.

-

Typical Internal surface finish certificates.

-

Specific internal surface finish certificates available at point of order request, and may be subject to 

additional cost.

-

Certificate of compliance for FDA, USP and ADI free.

-

TSE/BSE Free Statement.

-

Certificate of compliance EC1935:2004 Food Contact Materials.

-

Declaration of conformity BS EN ISO 14644-1:2015 Class 7 Clean Room.

Note:

 All certification/inspection requirements must be stated at the time of order placement, and may be 

subject to additional cost.

Note: 

For further product data see the following Technical Information Sheet, TI-P180-30

.

2. General product information

Summary of Contents for BT6-B

Page 1: ...product information 3 Installation 4 Commissioning 5 Operation 6 Spare parts and maintenance Copyright 2019 Printed in GB 1802950 11 BT6 B Sanitary Balanced Pressure Thermostatic Steam Trap Installat...

Page 2: ...IM P180 31 CMGT Issue 11 2...

Page 3: ...e product are lower than those of the system in which it is being fitted or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence ensure a safety device...

Page 4: ...or processed as persons inhaling the fumes from burning tobacco contaminated with PTFE particles can develop polymer fume fever 1 9 Tools and consumables Before starting work ensure that you have suit...

Page 5: ...re is taken Viton Can be landfilled when in compliance with National and Local regulations Can be incinerated but a scrubber must be used to remove Hydrogen Flouride which is evolved from the product...

Page 6: ...or example critical SIP applications please consult Spirax Sarco Standards The BT6 B has been designed and built in general accordance with ASME BPE The unit also complies with the requirements of the...

Page 7: ...IM P180 31 CMGT Issue 11 7 Fig 1 2 2 Sizes and pipe connections 1 and 1 sanitary clamp ends to ASME BPE For other end connections please consult Spirax Sarco...

Page 8: ...co Body design condition PN10 PMA Maximum allowable pressure 10 bar g 140 C 145 psi g 284 F TMA Maximum allowable temperature 177 C 9 2 bar g 350 F 133 psi g Minimum allowable temperature 254 C 425 F...

Page 9: ...self draining Check flow arrow for correct orientation Fittings clamps and gaskets for pipe end connections are not supplied Do not expose the element to superheat conditions since over expansion may...

Page 10: ...ent The operation relies on a stainless steel capsule that is filled with a temperature sensing fluid During cold or start up conditions the capsule will be fully open allowing large volumes of air co...

Page 11: ...These are the available spare parts No other parts are supplied as spares Capsule element assembly 3 and 5 Seal 5 Body outlet including seat 2 How to order spares Always order spares by using the des...

Page 12: ...carefully to ensure that the machined surfaces are not damaged Remove the sanitary clamps from the pipeline connections and remove the whole trap from the pipeline Remove the body sanitary clamp 4 th...