24.  All externally connected circuits for control, alarm and signalling must be supplied by SELV power sources (SELV 

according to DIN EN 60950-1). The current in these circuits must be limited to the values specified in the product 
documentation by means on an external fuse.  

25.  Before  applying  RF  power  to  the  product,  it  must  be  ensured  that  all  connecting  elements  are  professionally 

connected and all unused ports are terminated. RF connections must have sufficient mechanical strength.  If the 
product features an interlock system, it must be connected and tested for function in advance. 

26.  Unless expressly permitted, never remove the cover or any part of the housing while the product is in operation. 

Doing so will expose circuits and components and can lead to injuries, fire or damage to the product. 

27.  Repairs must be carried out by the manufacturer or technical personnel authorized by the manufacturer only. 
28.  As with all industrially manufactured goods, the use of substances that induce an allergic reaction (allergens) such 

as nickel cannot be generally excluded. If you develop an allergic reaction (such as a skin rash, frequent sneezing, 
red eyes or respiratory difficulties) when using a SPINNER product, consult a physician immediately to determine 
the cause and to prevent health problems or stress. 

29.  Broadcasting systems or improper use of this product may produce an elevated level of electromagnetic radiation. 

Considering that unborn babies require increased protection, pregnant women must be protected by appropriate 
measures.  Persons  with  pacemakers  may  also  be  exposed  to  risks  from  electromagnetic  radiation.  The 
employer/operator  must  evaluate  workplaces  where  there  is  a  special  risk  of  exposure  to  radiation  and,  if 
necessary, take measures to avert the potential danger. 

30.  In the event of a fire, the product may release hazardous substances (gases, fluids, etc.) that can cause health 

problems. Suitable measures must be taken, e.g. wearing of protective masks and protective clothing. 

31.  Products in operation may be hot. Touching them might cause burns. 
32.  If  the  product  is  pressurized,  applicable  local  or  national  safety  regulations  for  pressure  equipment  must  be 

observed. 

33.  Blocking of constructive openings on the product (ventilation slots, fine leaks etc.) must be prevented to ensure 

safe operation.  

34.  Before cleaning, disconnect the product and all transmitters connected to the product from mains. Use a soft, but 

not damp lint-free duster for cleaning. Do not use any chemical cleaning agents.   

35.  If handling the product releases hazardous substances or fuels that must be disposed of in a special way, e.g. 

coolants  that  must  be  replenished  regularly,  the  safety  instructions  of  the  manufacturer  of  the  hazardous 
substances and the applicable regional waste disposal regulations must be observed. Also observe the relevant 
safety instructions in the product documentation. The improper disposal of hazardous substances can cause health 
problems and lead to environmental damage. 

36.  The operator is responsible for disposing of the product according to national waste disposal regulations. Improper 

disassembly or disposal may be hazardous. 

37.  SPINNER RF switches are not equipped with separating equipment for safe disconnection from mains. The user 

must provide external separation equipment. The mains connector must be de-energized during plugging.  

38.  Do not actuate RF position 

I

 and RF position 

II

 of RF switches simultaneously to avoid RF switch damage. 

39.  Do not touch or block the emergency manual override during electrical switch over to avoid injuries and switch 

damage. 

40.  Disconnect RF switches from mains before using the emergency manual override of the drive unit to avoid injuries 

and switch damage. The emergency manual override serves solely for switching the RF switch manually in a dead 
state.  

41.  Switch over RF switches only without applying RF power to avoid injuries and damage. Hot switching with RF on 

is not permitted. Ensure all switches are in the respective end position before applying RF power.  

42.  Switch off RF power before disconnecting RF connectors to avoid burns, eye injuries and electric shock. Utilize 

appropriate devices and methods to prevent accidental energizing. 

 

Summary of Contents for BN 512690C0001

Page 1: ...Coaxial Two Way Switch DPDT RF Interface 7 16 Female BN 512690C0001 BN 512690C0002 BN 512690C0062...

Page 2: ...or 7 4 6 Interlock signal contacts 7 4 7 Earthing terminal 7 5 Data sheet 8 6 Outline all dimensions in millimeters 10 7 Circuit diagrams 11 8 Storage 13 9 Transportation 13 10 Installation 13 10 1 Me...

Page 3: ...d personnel with reference to Start up information in the product documentation Keep the basic safety instructions and the product documentation in a safe place and pass them on to the subsequent user...

Page 4: ...ly for people Therefore it is not permitted to use the handles for mounting on or at means of transportation e g cranes carts etc Lifting lugs serve for transportation or lifting with crane 13 Mains d...

Page 5: ...masks and protective clothing 31 Products in operation may be hot Touching them might cause burns 32 If the product is pressurized applicable local or national safety regulations for pressure equipmen...

Page 6: ...the information provided particularly the safety instructions is considered mandatory to comply with the intended use 4 Function 4 1 Impulse solenoid drive Switches with impulse solenoid drive genera...

Page 7: ...ocked in the end position 4 5 Visual position indicator The RF switch features a visual position indicator on the drive unit top side and on the bottom of the RF switch bottom side The position indica...

Page 8: ...tacts and signaling 25 pole connector according to DIN 41652 IEC 807 2 Operating Operating voltage BN 512690C0001 12 V DC 10 BN 512690C0002 21 6 to 28 V DC BN 512690C0062 21 6 to 28 V DC Operating cur...

Page 9: ...The maximum voltage can be applied up to 500 m or 1600 ft above sea level unless noted otherwise in the data sheet Above this height the maximum input power must be reduced as shown in the diagram De...

Page 10: ...lass 1 2 Ambient temperature 10 to 60 C Rain condensation icing Not allowed Standard conditions Dielectric Dry air under standard pressure at sea level p 1013 hPa Load VSWR max 1 0 no standing wave No...

Page 11: ...Data subject to change without notice M36311 Issue F www spinner group com 11 18 7 Circuit diagrams No B22676 CD Issue C valid for BN 512690C0001...

Page 12: ...Data subject to change without notice M36311 Issue F www spinner group com 12 18 No B24140 CD Issue D valid for BN 512690C0002 and BN 512690C0062...

Page 13: ...TION Sharp Edges Sharp edges may cause cuts and needle stick injuries Use safety gloves and handle carefully 10 Installation Before you start ensure to read and understand the Basic Safety Instruction...

Page 14: ...Use a torque wrench to tighten the bolted connections to 1 2 Nm bolt material A2 50 2 5 Nm bolt material A2 70 10 2 RF installation Remove the protection caps Align the system connectors carefully wi...

Page 15: ...fety Instructions and the additional safety instructions on personal safety that appear in relevant parts of this manual Failure to observe could result in death or serious injury Only trained electri...

Page 16: ...surface The RF switch heats up during normal operation Touching it may cause burns Do not touch the RF switch while hot Wait until completely cooled off Do not open the RF switch to avoid the risk of...

Page 17: ...TENTION The supplied packaging and all protection caps are reusable and required for transportation If not available contact SPINNER before starting demounting Do not stress the connectors and the man...

Page 18: ...26572 O GB T 26572 X Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirements of GB T 26572 Enterprises may fu...

Reviews: