BUILD IN GRILLING OVEN
INTEGRILL MODEL 5500-4BG

INSTALLATION INSTRUCTIONS

This appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas fitting regulations, municipal building codes, AG601 and any
other relevant statutory regulations.

DATA LABEL.

The data label is located on the right hand side wall, next to the hotplate burners, on the
outside. A duplicate data label is supplied to adhere to an accessible area next to the
appliance. Ensure that the gas supply is Propane. This appliance is designed for use
with Propane gas and should not be converted for use with any other gas.

VENTILATION

Ventilation must be in accordance with AG601 installation code. In general, the
appliance should have adequate ventilation for complete combustion of gas, proper
flushing and maintaining temperatures of the immediate surroundings within safe limits.

LOCATION

Choose a location free of draughts, open doors and clear of combustible materials and
other fire hazards. The location should ensure convenience of operation and service.
Any adjoining wall surface situated within 200mm from the edge of any hob burner must
be made from a suitable non-combustible material for a height of 150mm for the entire
length of the hotplate.

INSTALLATION

A cut-out should be prepared in the worktop and the front cupboard as shown below.

FITTING.

Place the appliance into the worktop/cupboard cut-out and connect to the gas supply as
detailed below.

CONNECTION

An 8mm gas inlet connection is provided on the underside of the appliance. Refer to
the "Dimensions" section following for the location of the gas inlet. It is recommended
that the appliance is connected by copper tubing using a 6mm male iron (1/4” BSP) to
an 8mm copper union.

MAINTENANCE

This appliance needs little maintenance other than cleaning. All parts should be
cleaned using warm soapy water. Do not use abrasive cleaners, steel wool or
cleansing powders. When cleaning the burner ring it is essential to ensure that the
holes do not become blocked. The control knobs are a push fit and can be removed for
cleaning. They are interchangeable without affecting the sense of operation.

THIS APPLIANCE MUST NOT BE MODIFIED OR ADJUSTED UNLESS
AUTHORISED AND CARRIED OUT BY THE MANUFACTURER OR HIS
REPRESENTATIVE. NO PARTS OTHER THAN THOSE SUPPLIED BY THE
MANUFACTURER SHOULD BE USED ON THIS APPLIANCE.

ABNORMAL OPERATION

Any of the following are considered to be abnormal operation and may require
servicing.
Yellow tipping of burner flame.

Sooting of cooking utensils.

Burners not igniting properly.

Burners failing to remain alight.

Burners extinguished by cupboard doors.

Gas valves that are difficult to turn.

WHO TO CONTACT

For service, please contact your authorised local Service agent giving full details of the
model, serial number and date of purchase

THIS UNIT IS SOLD AND SERVICED BY:-

DOMETIC PTY. LTD.

6 TREFOREST DRIVE

CLAYTON VICTORIA 3168

Tel (03) 9545-5655

496mm

45

5m

m

448

m

m

Cupboard Cutout

Worktop Cutout

Front of bench

Top of bench

More information https://www.caravansplus.com.au

Summary of Contents for INTEGRILL 5500-4BG

Page 1: ...FOR USE IN AUSTRALIA SPINFLO LIMITED 4 10 Welland Close Parkwood Industrial Estate Rutland Road Sheffield S3 9QY ENGLAND TEL 44 114 273 8157 FAX 44 114 275 3094 PCC1278Z Issue 1 WARNING Only use this appliance in a well ventilated area Read the instructions before use This appliance must be installed by an authorised person More information https www caravansplus com au ...

Page 2: ...t to the gas supply as detailed below CONNECTION An 8mm gas inlet connection is provided on the underside of the appliance Refer to the Dimensions section following for the location of the gas inlet It is recommended that the appliance is connected by copper tubing using a 6mm male iron 1 4 BSP to an 8mm copper union MAINTENANCE This appliance needs little maintenance other than cleaning All parts...

Page 3: ...Y Extinguish naked lights including cigarettes and pipes Do not operate electrical switches Open all doors and windows to disperse any gas escape Propane gas is heavier than air and any escaping gas will therefore collect at a low level The strong unpleasant smell of gas will enable the general area of the leak to be detected Check that the gas is not escaping from an unlit appliance Never check f...

Page 4: ...lling oven and clean the interior before using it for the first time Use soap and water and rinse carefully 3 To light open door push in the control knob and turn to full rate Hold a lighted match or taper to the burner and push the control knob in and hold The burner should ignite and the control knob should be held in for 10 15 seconds before release For models fitted with spark ignition the pro...

Reviews: