Checking for Breakage of the Heating Element & Cord Assembly

Disconnect the Plug and measure the resistance value

between the connecting Plug Pins as follows.

(See Figure 15)

a
b
c

Between Pin 4 & 5 (Heating Element)
Between Pin 1 & 2 (Sensor)
Between Pin 3 & Tip

2.5-3.5 (Normal)
43-58

(Normal)

About 2

W

W

W

(Figure 15)

(Figure 16)

If the values of ‘a’ and ‘b’ are outside the above value,

replace the Heating Element (sensor) and/or Cord

Assembly. If the value of ‘c’ is over the above value,

remove the oxidization film by lightly rubbing with fine

sand-paper or steel wool the points as shown in Figure 16.

1. Broken Heating Element

Measure when the Heating Element is at room

temperature (See Figure 17)

After replacing the Heating Element:

(Please see Figure 24 for details.)

1) Turn Nut (2) counterclockwise and remove the Tip

Enclosure(3), the Tip (4).

2) Turn Nipple (5) counterclockwise, remove it from the

lron.

3) Pull both the Heating Element (7),Terminal Board (8)

and the Cord Assembly (12) out of the Handle (9)

(toward the Tip of the lron).

1) Resistance value of Heating Element 2.5-3.5 W

2) Resistance value of Sensor 43-58 W. If the resistance

value is not normal, replace the Heating Element.

1) Measure the resistance value between

Pin 4 & 1 or 2

Pin 5 & 1 or 2

Disassembling the Iron unit

If it is not , the Heating Element and Sensor are

touching. This will result in damage of PWB.

1

2

3

4

5

14.

Measure the resistance value a, b, and c to confirm

tha tthe leads are not twisted and that the Grounding

Spring is properly connected.

2)

(Figure 17)

2. Broken Soldering lron Cord

There are two methods of testing the Soldering lron

Cord.

Turn the unit ON and set the Temperature Control Knob

to its maximum on the dial

(

). Then wiggle

and kink the lron Cord at various locations along its

length, including the strain relief area.(See Figure 18).

If the LED Heater Indicator flickers, the Cord needs to

be replaced.

896

480

1)

CAUTION:

The LED Indicator will flicker even

with a normal lron Cord if the temperature reaches

(

).

896

480

!

Check the resistance value between the Pin of the

Plug and the Wire on the Terminal.

2)

(Figure 18)

Pin 1: Black Pin 2: White

Pin 3: Green

Pin 4: Red

Pin 5: Blue

The value should be 0. If it is greater than 0 or is , the

Cord should be replaced.

Heating

Element

Sensor

15.

Replacing Fuse

Turn loose the Fuse Cover counterclockwise and remove

the blown Fuse, change a new one with the same rated

Fuse. (See Figure 19). Check the Specifications on page

18 for Fuse rating.

(Figure 19)

Fuse Box Cover

Counterclockwise

Fuse

Back Panel

16.

Summary of Contents for xg classic SGS-2000 series

Page 1: ...in China Normal use of this product could expose the user to solders containing lead which is known to the State of California to cause cancer and birth defects or other reproductive harm or other Pro...

Page 2: ...the Control Base to prevent any damage to the unit rap the Soldering Iron against any hard surface to shake off soldering residual or otherwise subject the iron to severe shock modify the unit Use on...

Page 3: ...h Iron Cord Assembly Plug Temperature Control Knob Front Panel Control Base Iron Holder Heating Indicator CAL Receptacle ESD Socket Back Panel Power Switch Fuse Fuse Box Power Plug Cord Assembly Solde...

Page 4: ...See Figure 8 Dampen the small Cleaning Sponge with water and then squeeze it dry Place it in one of the openings of the IronHolder See Figure 9 Add water daily to approximately the level as shown in F...

Page 5: ...nge Repeat until the oxides are completely removed Coat with new solder If the Tip is deformed or heavily eroded replace with a new one If any oxide film does form this can be cleaned by carefully rub...

Page 6: ...ng Element 1 Measure the resistance value between Pin 4 1 or 2 Pin 5 1 or 2 Disassembling the Iron unit If it is not the Heating Element and Sensor are touching This will result in damage of PWB 1 2 3...

Page 7: ...ated correctly Refer to Calibrating the Iron Temperature 9 Is the Tip seized Is the Tip swollen because of deterioration Replace the Tip and the Heating Element Check 8 Check 8 10 The indicator is not...

Page 8: ...Base Housing PWB Insulator Transistor Fastening Plate Front Panel Assembly Front Panel Front Panel Plate Front Panel Plate Potentiometer Mount Temperature Control Knob Five Pin Socket CAL Pot Plug Wat...

Page 9: ...GI 980 SGI 980S Soldering Iron Soldering Iron Nut Tip Enclosure Soldering Iron Tip Nipple Nipple Spring Heating Element Terminal Board Handle Handle Handle Cover Handle Cover Iron Cord Bushing Solderi...

Reviews: