SK599-AT5
Operating the truck
Truck
3-28
SPIERINGS MOBILE CRANES USER MANUAL V 0.1
D
ec
2
01
6
C
h
an
ges
an
d t
y
po
gr
ap
hi
c
al
er
ro
rs
res
er
v
ed.
©
20
1
6
S
pi
er
ings
M
obi
le
C
ran
es
–
A
ll r
ight
s
re
se
rve
d
.
3.9.2.3.
Main screen: Information screen
By means of
switch 6
on the control panel, the
information
screen
) can be called.
In this screen, both the
passive
and the
current error messages
are displayed.
Passive error messages
(PAS) are messages, which already have been corrected and after shown as
passive on screen once, they will disappear.
The
passive error messages
can then no longer be shown on the information screen.
The
current error messages
(ACT) keep coming back when they are not corrected.
A. Time counter diesel engine [hours];
B. Ambient temperature [°C];
C. Indication oil level [%]:
-
Flashing (1 Hz) when level is not measurable;
-
Flashing (2 Hz) when communication with CAN-bus is lost;
D. Indication beam oil pressure [%];
-
Flashing (2 Hz) when communication with CAN-bus is lost;
E. Recent error codes of the diesel engine:
-
If there are no recent errors, then this part of the screen is blank;
F. Activity of the CAN-bus participants:
-
Active if the text appears black in a white background;
-
Not active if the text appears white in a black background.
Picture 3-14