2. Apply the minimum loads listed in Chapter 3.4 to the centre of the Spider 8 in
accordance with AC 43.13-2B, Para 105. Record the actual applied loads:
(B)6.Pass/Fail Criteria
When no damage or permanent deformation occurs after 7 seconds of applied static load in
all directions, the Spider 8 installation is acceptable. Should permanent deformation occur
after 3 seconds, reinforcements are required (e.g. doubler installation) to the affected
structure and repeat test.
(B)7.Test Record
Forward
Downward
Upward
Side
Date of Test
Spider 8 S/N
Location of Test
A/C Registration
LAME conducting
testing:
Print Name
Signature
License No.