16
The Spidertracks system comes with a two tiered emergency management framework,
which are aligned with the ICAO definitions of
uncertainty
and
alert
. Recipients of these alert
notifications are fully customisable within the Organisational Settings of the website.
3.2. Watch Button
The Watch button has two purposes:
1. To manually activate/deactivate the watch system at any stage of flight when operating
in normal reporting mode; or,
2. To turn the Watch system off when operating under automated watch mode. Note that
the aircraft must be below the configured speed threshold in order to disable the watch
system when operating in automated watch mode.
The watch button will toggle on/off - do not press and hold the button. When disabling the
system the LED indicator will begin to flash once toggled. The Spider has now sent a watch-
off message. Until the message has been sent successfully, the LED will continue to flash. It
is normal operation for this to take up to 60 seconds. While this is in process the aircraft
must remain in full view of the sky. If the Spider is powered off before transmitting the watch-
off message, a tier one alert will be raised.
3.3. Radius Button
Radius is a dynamic exclusion zone of a preconfigured size within the Organisational
Settings of the website. When the Radius button is toggled on, position reporting is
suspended while the aircraft operates within the bounds of that geo-fenced area. Tracking
will resume on exiting the radius area or toggling off the Radius button. For information on
configuring Radius please refer to User guide and videos for the spidertracks website.
3.4. Mark Button
Up to four pre-programmed macro messages can be delivered by way of toggling the Mark
button the corresponding number of times, i.e. a single toggle will trigger Mark 1 message
to be sent, toggling twice will trigger Mark 2 message to be sent. Each message is geo-
stamped and includes all other parameters of a standard position report.
Configuration of macro messages, recipients and delivery mechanism are configured within
the Organisational Settings of the website.
3.5. SOS Function
A tier-one alert can be initiated immediately by pressing the Radius and the Mark buttons
together. When the SOS function has been toggled all LEDs across the top of the keypad
Summary of Contents for Spider 8
Page 11: ...10 Case 2 Case 3 Case 4 Case 5 ...
Page 12: ...11 Case 6 Case 7 Case 8 ...
Page 26: ...25 ...
Page 32: ...31 D Wiring Diagram Power Lead ...
Page 33: ...32 E Datasheet for Iridium GPS S67 1575 109 ...
Page 34: ...33 F RTCA DO 160 Test Reports View DO 160 reports from our Support Website ...