- During heating, there may be drops of water dripping

  from the pressure release hole of the multifunction    

  valve. This is a normal occurrence. If there is a large   

  amount of water leaking, please contact Spherehot 

  customer care center for repair. This pressure release 

  hole shall, under no circumstances, be blocked; 

  otherwise the heater may be damaging, even resulting  

  in accidents.

- The drainage pipe connected to the pressure release

  hole must always be kept sloping downwards.

- Since the water temperature inside the heater can

  reach up to 70°C-80°C, the hot water must not be

  exposed to the human body when it is initially used.

  Adjust the water temperature to a suitable   

  temperature to avoid scalding.

- Unscrew the thread screw on the multifunction

  safety valve, and lift the drain handle upwards to drain

  water from the inner tank.

- Manually operate the safety valve on a regular basis

  by lifting the drain handle to remove lime deposits, if

  any, and to verify that it is not blocked.

- If the flexible supply cord is damaged, it should be

  replaced by professional maintenance personnel with   

  a new supply cord available with the manufacturer.

- If any parts and components of this electrical water

  heater are damaged, please contact Spherehot

  customer care center for repair.

MAINTENANCE

- Check the power supply plug and socket frequently

  to make sure that they have good, reliable contact    

  and are well grounded without overheating.

- If the heater is not used for a long time, especially in

  regions with low atmospheric temperature (lower  

  than 0°C), the water inside the heater must be  

  drained away. This will prevent damage to the heater 

  due to frozen water in the inner container.

- In order to ensure that the water heater operates

  efficiently for a long time, it is recommended that you

  clean the inner container and the deposits on the

Note: 

Parts illustrated in this use and care manual 

are indicative only, parts of the product may differ 

from the illustrations. This product is intended for 

household use only. Specifications are subject to 

change without notice.

  electrical heating components periodically.

- It is mandatory to examine the magnesium anode

  protection material every six months or earlier to

  enhance the life of the inner tank and heating element.   

  If the magnesium anode is fully consumed, the same  

  must be replaced on a chargeable basis

WIRING DIAGRAM

Thermal cut-out

Fig.06

Thermostat

230 V/50 Hz AC

Red

Black

Green

Power indicator

Heating indicator

Heating element

Summary of Contents for CYLENDRO MGL I

Page 1: ...eri Kurla Road Andheri East Mumbai 400093 18001202700 9833002020 WEEE ENVIRONMENTAL PROTECTION Disposal of Electrical and Electronic Equipment Do not dispose of this product with household waste For it s proper treatment recovery and recycling please take this product to the appropriate waste collection point If you are unsure where this may be please contact your local authority Improper disposal...

Page 2: ...e Adjustable Knob 3 Water Inlet Please read and follow all the instructions given in this use and care manual carefully before using your Spherehot Cylendro MGL I to get the best mileage and trouble free operation FEATURES OF THE CYLENDRO MGL I ...

Page 3: ...box There should be some distance between the unit and the roof This is to ensure that the unit can be removed easily when required The unit should also be saved from damaged due to splashing water For this keep a minimum distance of 1 2m between the floor and bottom of the heater The water heater must be connected to the water mains by new detachable hose pipes Old hose sets should not be used Al...

Page 4: ...nk If the Users want to realize a Multi Way Supply System refer to the method shown in Fig 3 Connection of the Pipelines First Open any one of the Outlet Valves at the Outlet of The Water Heater Open the Inlet Valve The Water Heater gets filled with Water When water flows out of the Outlet pipe it Implies that the Heater has been filled fully with Water and the Outlet valve can be closed Note Duri...

Page 5: ...ear a load of more than two times the heater when fully filled with water Other strengthening measures must be adopted in case of distortion and cracks The multifunction valve attached to the heater must be installed at the cold water inlet This valve performs the function of pressure release vacuum release non return and drainage When using the heater for the first time or during first use after ...

Page 6: ... If any parts and components of this electrical water heater are damaged please contact Spherehot customer care center for repair MAINTENANCE Check the power supply plug and socket frequently to make sure that they have good reliable contact and are well grounded without overheating If the heater is not used for a long time especially in regions with low atmospheric temperature lower than 0 C the ...

Reviews: