During normal operation, emergency mode should NOT be set. Emergency mode 

is only used if the operating panel is malfunctioning. 

  This mode is not suitable for long periods of food storage. If the switch is in the 

“EMERGENCY OVERRIDE” position, the refrigerator is set to full cooling capacity. 
Super-cooled temperatures may be seen and will freeze the items within the unit. 

 

VI. Setting the Low battery cut out (Low voltage protection) 

-When powered from a vehicle 12/24VDC Aux power outlet, if no Aux charging system is 

used to maintain the battery (Solar panels etc.) the AUX battery voltage will decrease with 

use  and  the  compressor  will  stop  working,  so  as  to  protect  the  battery  against  over 

discharge.  Once  the  battery  voltage  reaches  the  restarting  voltage  (after  charging),  the 

compressor will start immediately and resume normal operation.   

-When the battery voltage is too low, the electronic battery protector will take effect. 

The  Red  malfunction  indicator  light  will  blink.  Recharge  the  battery  to  resume  normal 

operation. 

 

Voltage cut out range of electronic battery protector: 

Power Supply   

Status Battery protector   

Low

 Mode 

Medium

 Mode 

High

 Mode 

DC 12V 

Cut out Voltage 

10.1

±

0.3V 

11.4

±

0.3V 

11.8

±

0.3V 

Restarting Voltage 

11.1

±

0.3V 

12.2

±

0.3V 

12.6

±

0.3V 

DC 24V 

Cut out Voltage 

21.5

±

0.3V 

24.1

±

0.3V 

24.6

±

0.3V 

Restarting Voltage 

23.0

±

0.3V 

25.3

±

0.3V 

26.2

±

0.3V 

When  the  refrigerator  power  is  supplied  by  the  Main  Vehicle  starting  battery,  HI 

mode setting is 

recommended

, so as to warrant that vehicle’s battery power is still able to 

start the vehicle when required. Please contact your local Auto electrician as many options 

are available for aux battery fitment.   

If you use additional AUX battery as a power supply, Lo and Med mode setting is available 

for  extended  use  and  operation.  Please  refer  to  the  battery  specifications  for  maximum 

recommend discharge voltages to ensure battery performance.     

Should the power supply be interrupted the Refrigerator is designed to restore the 

previously set temperature settings when power is restored again. 

Summary of Contents for RVX-35

Page 1: ...ION MANUAL PORTABLE FRIDGE FREEZER Models RVX 35 RVX 45 RVX 50 RVX 55 RVX 65 RVX 75 PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE CONNECTING AND OPERATING THE APPLIANCE SAVE IT FOR FUTURE REFERENCE V1 1 ...

Page 2: ...tage cutout low voltage protection 8 Defrosting 9 Replacing fuse and light PCB 9 Cleaning and maintenance 10 Troubleshooting 11 Packing list and Warranty information 12 Notice Please pay attention to the below markings Safety cautions non standard operations could endanger personal safety or Result in refrigerator damage Hints for operation ...

Page 3: ...t to make sure the refrigerator is able to achieve rapid cooling performance Supplied with full sized removable storage basket with divider for item separation and ease of cleaning Using microprocessor control with touch control buttons and LED display this allows for accurate control of the temperature 22DegC 10DegC With low voltage protection and reverse polarity protection When used for drug co...

Page 4: ... direct sunlight Make sure the appliance is used in a well ventilated area for normal operation The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision use of the appliance by a person responsible for their safety Children should be supervised to ensure that ...

Page 5: ... socket making sure it is either a DC 12V 24V outlet When using Mains power of AC 100 240V please insert the AC plug into an AC socket And remove the 12 24VDC power lead from the appliance at this time During normal operation emergency mode is not applicable Emergency mode is only used while the operating panel is malfunctioning 2 Operating panel ...

Page 6: ... 10 C Press button once again to adjust the display type from centigrade degree C to Fahrenheit degree F Press either to swap between C and F display modes The cooling temperature appears in the display for a few seconds The display flashes several times and then the interior temperature is displayed again NOTE If the ambient temperature is above 32 C 90 F the minimum temperature cannot be attaine...

Page 7: ...onic battery protector mode Digital display will be as follows Lo LOW ΠE MED HI HIGH The selected mode then appears in the display for a few seconds The display flashes several times before it returns to the current temperature Please refer to Page 8 Voltage chart for the different battery cut out voltages 6 Turning off the refrigerator In normal operation press button for three seconds to turn of...

Page 8: ...ffect The Red malfunction indicator light will blink Recharge the battery to resume normal operation Voltage cut out range of electronic battery protector Power Supply Status Battery protector Low Mode Medium Mode High Mode DC 12V Cut out Voltage 10 1 0 3V 11 4 0 3V 11 8 0 3V Restarting Voltage 11 1 0 3V 12 2 0 3V 12 6 0 3V DC 24V Cut out Voltage 21 5 0 3V 24 1 0 3V 24 6 0 3V Restarting Voltage 23...

Page 9: ... off the defrosted water A Drain bung is provided in the base of the compartment Please ensure this is over a suitable drain or open ground if used to drain away any water from the internal base Ensure this is reinstalled before normal use of the appliance once defrosting is completed Never use hard or pointed tools to remove ice or to loosen objects that may have frozen in place VIII Replacing fu...

Page 10: ...r with a screwdriver Unscrew the PCB mounting board Pull out the connector wire terminal from the PCB Replace the defective light PCB with a new one Fit new PCB using reverse of removal instructions Press the transparent cover back into the housing IX Cleaning and Maintenance Warnings Always disconnect the appliance from the Power Mains or DC supply power before you clean and service it Warnings D...

Page 11: ...ance The device does not cool plug is inserted POWER LED flashes orange display is switched off Battery voltage is too low Test the battery and charge it as required Temperature control Temperature control panel broken Please contact Sphere Service centre for further assistance Emergency mode Slide the emergency switch to normal mode Error indicator light blinks Compressor operating trouble It wil...

Page 12: ...S 24MONTHS Compressor part supply only Warranty In Australia our Goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the Goods repaired or replaced if the Goods fail to be of acceptable quality and th...