NOTICE:  

1. Consult the GFCI manufacturer's installation instructions to determine that the GFCI is installed in accordance with the 
manufacturer's specifications.  
2. Check for correct wiring of receptacle and all remotely connected receptacles on the branch circuit.  
3. Operate the test button on the GFCI installed in the circuit. The GFCI must trip. If it does not — do not use the circuit 
— consult an electrician. If the GFCI does trip, reset the GFCI. Then, insert the GFCI tester into the receptacle to be 
tested.  
4. Activate the test button on the GFCI tester for a minimum of 6 seconds when testing the GFCI condition. Visible 
indication on the GFCI tester must cease when tripped.  
5. If the tester fails to trip the GFCI, it suggests: a.) a wiring problem with a totally operable GFCI, or b.) proper wiring 
with a faulty GFCI. Consult with an electrician to check the condition of the wiring and GFCI. 
 

Caution:

 GFCIs are sometimes installed in 2- wire systems (no ground wire available). This may or may not meet the 

local code. This tester will not trip GFCI outlets installed without a ground wire. On two wire systems use the test and 
reset buttons on the GFCI outlet to demonstrate proper operation. To detect which downstream outlets are protected 
by the GFCI place the tester in these outlets and use the test and reset buttons. Watch for the LEDs on the tester to turn 
off, this will indicate proper operation. 

 

 

Battery Instructions:  

No batteries need for this unit 

 
 

 

CAUTION: 

REFER TO THIS MANUAL BEFORE USING THIS TESTER 
DO NOT ATTEMPT TO REPAIR THIS TESTER. IT CONTAINS NO SERVICEABLE PARTS 

 

 

Double Insulation: 

The tester is protected throughout by double insulation or reinforced insulation. 

 
 

Warning – 

This product does not sense DC voltage  

 

Warning – 

To assure the unit is operating, always test on a known live circuit before use. 

 
 

Limited Lifetime Warranty

 limited solely to repair or replacement; no warranty of merchantability  

or fitness for a particular purpose. Product is warrantied to be free of defects in materials and  
workmanship for the normal life of the product. In no event shall Sperry Instruments be liable for incidental or 
consequential damage.       

 