background image

7

Transducer

840066

840067

840068

840069

840070

Max

Range

Res.

Max

Range

Res.

Max

Range

Res.

Max

Range

Res.

Max

Range

Res.

Bar

2

0.002

5

0.005

10

0.01

 20

0.02

50

0.05

PSI

29

0.02

72.5

0.1

145

0.2

290

0.2

725

1

Kg cm

2

2.040

0.002

5.095

0.005

10.19

0.01

20.40

0.02

50.95

0.05

mm Hg

1500

2

3750

5

7500

10

15000

20

37500

50

In Hg

59.05

0.05

147.6

0.1

295.2

0.2

590.5

0.5

1476

1

Meter H

2

O

20.40

0.02

50.95

0.05

101.9

0.1

204.0

0.2

509.5

0.5

In H

2

O

802

1

2006

2

4010

5

8020

10

20050

20

Atmospheres

1.974

0.002

4.935

0.005

9.87

0.01

19.74

0.02

49.35

0.05

SPECIFICATIONS - TRANSDUCERS

SPECIFICATIONS - METER

Circuit

Microprocessor LSI circuit.

Sensor type

Works with optional 2, 5, 10, 20, 50, 100, 200 bar 

sensor, new calibration is not necessary when the 

sensor is changed.

Measuring units

Bar, Psi, Kg/cm

2

, mm/Hg, inch/Hg, meter/H

2

O, 

inch/H2O Atmosphere.

Accuracy

± 0.5% + 1d, within 23°C ± 5°C

Zero adjust

Push button on the front panel.

Span adjust

Push button gain adjustment for precise calibration.

Input signal  

from sensor

DC 100 mV for full scale.

Data output

RS 232 PC serial interface. 

Sampling time

Approx. 0.8 second.

Operating Temp.

0 to 50°C (32 to 122°F), Less than 80% R.H.

Power supply 

Alkaline or heavy duty type DC 9V battery, 006P, 

MN1604 (PP3) or equivalent.

Power current 

Approx. DC 7.0 mA.

Dimensions

7" × 3" × 1½" (178 × 76 × 38 mm)

Weight

13 oz (369 g)

Summary of Contents for 840065

Page 1: ...Wide Range Pressure Meter 840065 Instruction Manual...

Page 2: ...do not yet exist or may be developed including photocopying recording or any information storage and retrieval system without the express permission from Sper Scientific INTRODUCTION 3 PANEL DESCRIPTI...

Page 3: ...ulic servo controls refrigeration air conditioning and food processing Features eight units of measure Bar Psi Kg cm mm 1meter H20 inch H20 Atmosphere min max hold and auto power off PANEL DESCRIPTION...

Page 4: ...ype 4 Push the SENSOR TYPE Button to select the sensor 2 5 10 20 50 100 or 200 Bar When the display indicates the desired sensor push the Zero button The new sensor type will be stored in memory even...

Page 5: ...nt reading Measuring Procedures Overview 1 Connect the Sensor Plug to the meter s Input Socket 2 Turn on the meter 3 Select the display unit 4 Zero the meter by pressing the ZERO Button 5 Connect the...

Page 6: ...it to warm up for two minutes 2 Push the ZERO Button 3 Connect the pressure regulator to a nitrogen bottle and the reference gauge to the pressure regulator 4 Press and hold both the MAX MIN Button a...

Page 7: ...ATIONS TRANSDUCERS SPECIFICATIONS METER Circuit Microprocessor LSI circuit Sensor type Works with optional 2 5 10 20 50 100 200 bar sensor new calibration is not necessary when the sensor is changed M...

Page 8: ...does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will break the waterproof seal a...

Reviews: