Sper scientific 800105 Instruction Manual Download Page 6

DISTANCE-TO-SPOT 

The distance-to-spot ratio is 12:1.  As the distance from the 
object increases, the spot size of the area measured also 
increases. 

11 

ADVANCED FUNCTIONS 

High Alarm (HAL) 

 
1.  Pull the 

Trigger 

(3), then press the 

Function 

(19) but-

ton until 

HAL 

(12)

 

appears on the display. 

 

2.  Use the ▲ or 

 buttons to set the high alarm value. 

 

3.  The Thermometer will beep when the temperatire 

reading is higher than the alarm setting. 
 

4.  When the adjustments are complete, the thermometer 

will return to the 

SCAN 

(8) mode after approximately six 

seconds 

Low Alarm (LAL) 

 
1.  Pull the 

Trigger 

(3), then press the 

Function 

(19) but-

ton until 

LAL 

(12)

 

appears on the display. 

 

2.  Use the ▲ or 

 buttons to set the low alarm value. 

 

3.  The Thermometer will beep when the temperatire 

reading is lower than the alarm setting. 
 

4.  When the adjustments are complete, the thermometer 

will return to the 

SCAN 

(8) mode after approximately six 

seconds 

Summary of Contents for 800105

Page 1: ...I R Thermometer Gun 12 1 800105 Instruction Manual SPER SPER SPER SPER SCIENTIFIC SCIENTIFIC SCIENTIFIC SCIENTIFIC...

Page 2: ...ription 4 5 Distance to Spot 6 Measurement Procedures 7 Advanced Functions 8 11 Cleaning 12 Specifications 12 Standards 12 Battery Replacement 13 Notes Precautions 13 PLEASE REVIEW NOTES PRECAUTIONS B...

Page 3: ...f why you are returning the item Mail your warranty card within 10 days or register on line at www sperscientific com Revised 10 31 2007 Caution this symbol indicates that equipment and its accessorie...

Page 4: ...operate or service the IR Gun Only qualified technicians should perform repairs DO NOT submerge the IR Gun in water Protect the IR Gun from water shock dust and extreme environments The IR Gun may be...

Page 5: ...n the housing with mild soap on a cloth or sponge STANDARDS EN61326 Electrical equipment for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge immunity IEC61000 4 3 Radiated...

Page 6: ...ill beep when the temperatire reading is higher than the alarm setting 4 When the adjustments are complete the thermometer will return to the SCAN 8 mode after approximately six seconds Low Alarm LAL...

Page 7: ...tween the highest max and the lowest min recorded temperature from the time the Trigger is pulled to when it is released 3 Release the trigger and use the Function 19 button to cycle through MAX MIN A...

Page 8: ...ll continuously scan 6 Press the Function 19 button again to exit Auto 10 mode 9 Data Record 1 Pull the Trigger 3 then press the Function 19 but ton until DATA 15 followed by a number from 0 to 9 appe...

Reviews: