ModelMatch
The DX3C features ModelMatch technology that prevents operating a model using the wrong model memory. During the binding
process, the receiver stores code that is assigned to the specific model that is currently selected in the transmitter. For example: if
the model that is selected in the transmitter is model #3, when a receiver is bound to that transmitter, the receiver will only operate
when model #3 is selected. If another model memory is selected (model #5 for example) the receiver will not connect. If model #3
is again selected in the transmitter, the receiver bound to model #3 will connect. ModelMatch prevents operating a model using the
wrong model memory.
MAIN SCREEN
The
Main Screen
displays information about the selected model such as trim positions, timer, the model selected, battery voltage,
etc. This screen shows the Timer only when activated.
Note:
An alarm will sound when the transmitter’s battery voltage goes below the value set in the
System Screen
.
Note:
An alarm will sound when the timer gets to the limit (DOWN) set in the
Timer Screen
.
While in any screen, press and hold the Rolling Selector for more than 3 seconds to return to the
Main Screen
.
Throttle (TH) and Steering (ST) trim positions show as blocks in rectangles.
A
Transmitter battery voltage.
B
Name assigned to the Model memory.
C
Active Model memory number (20 available).
D
User Name.
E
Position of Throttle (Th) trim.
F
Position of Steering (St) trim.
G
Timer (when activated).
H
Model number and name (Timer activated).
Spektrum Th
Model 1:
NAME-O1
St
5.7V
C
E
D
F
B
A
Th
1:
XXX T
TM
10:00
St
5.7V
G
D
E
F
A
WARNING SCREENS
Low Battery Alarm
An alarm will sound and a warning screen will show when the transmitter’s battery power goes
below a set limit. This alarm reminds a user to bring a model under full control, power off the trans-
mitter and replace batteries. Press the Roller to stop the alarm and go to the
Main Screen
.
Set the low battery limit using the
System Screen
.
A
Warning title
B
Battery voltage which is under the set limit
C
Animated arrow pointing to Roller below screen
D
Image of roller below screen.
ENTER
Battery Low
B
A
D
C
4.3V
Inactivity Alarm
An alarm will sound and a warning screen will show when the transmitter has been left on
(approximately 10 minutes) without control movement. Moving any control will stop the alarm.
This alarm reminds users to power off the transmitter and save battery power.
Warning
Inactivity