SPEEDKEY

IMPORTANT NOTES

SK-AC2000

Dear User: 
Welcome to join the user group of SPEEDKEY! 
We sincerely hope that this new model can bring you joyful experiences. 

IMPORTANT NOTES

PACKAGE COMPONENTS

  Electric Room Thermostat (detachable

SK-AC2000SYS 

  Electric Room Thermostat 

(

integral

SK-AC2000I

INTRODUCTION

PRODUCT WIRING

·

·

 

·

Electric Room Thermostat

Electric Room Thermostat 

·

 

·

 

·

·

·

This manual must be read before installation

   Please read carefully this

 

manual before installation

fully

 

understand

 

the

 

principle

 

and

 

function of    

   this product.

PRODUCT SAFETY

 

   All SPEEDKEY

 

products

 

have

 

been

 

designed

 

and

 

produced

 

in

 

accordance

 

with

 

CE and RoHS

   

   requirement

with

 

various

 

performance

 

indexes

 

complying

 

with

 

BS4662

 

requirements

Incorrect

    

   wiring

 

may

 

cause

 

burning

-

out

 

or

 

malfunctions

Please

 

refer

 

to

 

the

 

wiring

 

diagram

 

for

 

specific

 

   details

Please check whether the wiring diagrams contravene local access wiring rules.

(

integral

)

   

Touch Panel can be installed in BS4662

 

switch

 

box

It is recommended   

   that

 

its

 

internal installation

 

dimension

 

of

 

base

 

box

 

is

 

65mm

*

65mm

*50

mm

.

Its

 

external

 

dimensions

     

   of

 

the producuct  is

 

86 mm

*

86mm

*

46mm

.

The

 

wiring

 

terminal

 

can

 

be

 

either

 

screw

 

type

 

or non

-

screw

  

   type

The

 

switch

 

can

 

be

 

used

 

safely

 

only

 

when

 

connected

 

to

 

live

 

line

neutral line and earthing

  

   line

.

Room Temperature Controller

 (

detachable

)

   Touch Panel

 

can

 

be

 

installed in BS4662

 

switch

 

box

It is recommended that its internal  installation   

 

 

dimension of base box is 65mm

*

65mm

*50

mm

.

Its external dimensions of the touch panel

 

is

 

86    

   mm

*

86mm

*

18mm

,

 which

 

shall be connected to the host with 6-core cables.

SK-AirC-Remote Infrared remote

 

controller

 

   With infrared transmitter

 

in

 

this

 

remote controller

its operating

 

range

 

is more than 15m

 

in

 

free

 

space

 

 its remote control angle is less than or equal to 90 degrees, and the infrared ray can be reflected indoors

.

PROPER POSITIONS FOR INSTALLATION

 

   1

The

 

positions

 

shall

 

be

 

convenient

 

for

 

easy

 

installation

 

and

 

operation

.

   2

The positions shall be away from water, moisture

direct sunlight and dust.

TROUBLE SHOOTING GUIDE

   If the product can not work properly after the installation, please refer to TROUBLE SHOOTING GUIDE

 

in

    

   this

 

manual

.

   Please use dry, soft cloth material for cleaning. Do not clean the switch with anti-solvents such as   

   alcohol, acetone and ether etc.

WARRANTY

   SPEEDKEY

 

products

 

come

 

with two years

equipment

-

only

 

warranty

.

 

PRODUCT INSTALLATION

PRODUCT FUNCTION OPERATION

  Electric Room Thermostat

 (

integral

 

SK-AC2000I

NSR-Single valve circuit

 

diagram

  Electric Room Thermostat

 (

detachable

 

SK

-

AC2000SYS)

 

SR-Single valve circuit

 

diagram

  Electric Room Thermostat

 (

detachable

 

SK

-

AC2000SYS

NSR-Single valve circuit diagram

  Electric Room Thermostat

 (

detachable

 

SK

-

AC2000SYS

SR-Double

 

valve

 

circuit

 

diagram

  Electric Room Thermostat

 (

integral

 

SK-AC2000I

SR-Single valve circuit diagram

  Electric Room Thermostat

 (

detachable

 

SK

-

AC2000SYS

NSR-Double

 

valve

 

circuit

 

diagram

Illustration of SK-AC2000

 

Series

 

Introduction of SK-AC2000

 

Screen 

Description of SK-AC2000

 

Remote Control 

PARAMETER SETTING

PRODUCT SPECIFICATIONS
TROUBLE SHOOTING GUIDE

16 / 18

22

23

Electric Room

 

Thermostat

19 /20

PROGAMMING SETTING

21

Summary of Contents for SK-AC2000

Page 1: ...the manual before using the product Please preserve properly for future reference PRODUCT 2 0 0 8 SK AC2000 USER MANUAL Electric Room Thermostat www speed key com SPEEDKEY TECHNOLOGY CO LTD SPEEDKEY TECHNOLOGY CO LTD ON OFF SPEED ...

Page 2: ... 65mm 50mm Its external dimensions of the touch panel is 86 mm 86mm 18mm which shall be connected to the host with 6 core cables SK AirC Remote Infrared remote controller With infrared transmitter in this remote controller its operating range is more than 15m in free space its remote control angle is less than or equal to 90 degrees and the infrared ray can be reflected indoors PROPER POSITIONS FO...

Page 3: ...ON OFF SPEED CR2025button cell SK AirC Remote Controller of 2 fixing screws 速 度 开 关 ON OFF SPEED HOUR MIN SET DOWN DEFAULT UP YEAR MONTH DAY Remote for staff only ON OFF HIGHT LOW MID MODE HEAT COOL Electric Room Thermostat detachable SK AC2000SYS Controller panel Host of the controller Fixed bracket Manual SK AirC Remote Controller of CR2025 button cell 2 fixing screws PRODUCT 2 0 0 8 SK AC2000 O...

Page 4: ...ate clearly in any environment even it is dark Its intelligent circuit control has 3 steps of wind speed control there are 3 optional modes which is cooling mode heating mode and automatic mode can be set by infrared remote SK AC2000 can replace traditional mechanical air conditioning temperature controller and it can effectively save more than 30 energy Electric Room Thermostat Electric Room Ther...

Page 5: ...el valve control neutral line output earthing line output earthing line input Neutral line input 100 200V AC live line input Air conditioning touch control panel 6 bit control terminals Fan coil Cooling and heating water valve Electric Room Thermostat see figure detachable SK AC2000SYS NSR Single valve circuit diagram 6 bit control terminals weak current control connection wire Host for air condit...

Page 6: ... 200V AC live line input Fan coil Cooling water valve heating water valve detachable SK AC2000SYS SR Double valve circuit diagram see figure Electric Room Thermostat Remark SR s self elastic spring valve can close automatically when the power is off Air conditioning touch control panel 6 bit control terminals 6 bit control terminals weak current control connection wire Host for air conditioner con...

Page 7: ... circuit 2 Open the switch base box of touch screen panel with the screwdriver Dismounting hole 3 Check Bs4662 switch base box whether there is enough space 50mm to install touch screen switch If the space is not enough the thickening bracket shall be used 4 Draw out strong electric cable and network cable from Bs4662 switch base box and trim up press tightly on terminal block as illustration Wiri...

Page 8: ...erminal Connecting method of screw terminall Please use single wire of diameter of 1 6 or 2 0 to comply with non screw terminals suitable cable Please use single or multi copper wire of diameter less than 4mm to comply with screw terminals suitable cable 5 Mount the switch driving section into base box and fix with 2 screws 6 Insert the wiring terminal of switch driving section into the touch scre...

Page 9: ... 关 ON OFF SPEED 速 度 开 关 ON OFF SPEED 7 Cover the touch screen panel 8 Set program setting as you like Illustration for installation of detachable SK AC2000SYS Electric Room Thermostat SK AC2000T air conditioning control panel bracket wall BS4662 switch base box 6 cored cable SK AC2000M air conditioning controller strong current cable fan coil Fix the host beside the fan coil controller ...

Page 10: ... the function of timing and advanced time setting EEPROM can permanently keep parameters set by the user during power cut Various valves SR NSR can be controlled It can save effectively more than 30 energy SK AC2000 intelligent is suitable for installation in standard Bs4662 switch base box Electric Room Thermostat Introduction of SK AC2000 display screen Heating mode Cooling mode Operating status...

Page 11: ...estarts The system will automatically affirm the setting in LCD screen and display the corresponding static icon Cooling mode the system cooling setting must be set up with the remote controller Press MODE button and press button and set summer cooling mode Its default temperature is 26ºC when this system restarts The system will automatically affirm the setting of LCD screen and display the corre...

Page 12: ...tion to facilitate its management It will lock the system if necessary Lock The lock function can be achieved only with the remote controller Press the SET button once at first then press the button to lock the system Unlock the unlock function can also be achieved only with the remote controller Press on the remote controller and unlock the system Note if the power is off this setting will be can...

Page 13: ...ontrolled equipments No shut off of air conditioner Ceaseless Flash fo r touch screen Possible cause Solutions 1Incorrect wiring or poor contact 2 Main switch or creepage protection switch is off 3 No neutral line connected of the system 4 Burnt fuse 5 Auto protection of the system 1 Unstable Voltage too much interference 2 Incorrect wiring 3 Shut by remote controller 1 Overload current 1 Broken o...

Page 14: ...SPEEDKEY TECHNOLOGY CO LTD Specifications subject to change without notice 2008 All rights reserved www speed key com ...

Reviews: