<4>
E
N
G
L
I
S
H
Speedaire Operating Instructions and Parts Manual
3CRH6A
H
Speedaire
3/16 ~ 1/4”
Air Riveter
®
TROUBLE SHOOTING
Stop using the tool immediately if any of the following problems occurs. Any repairs or replace-
ments must be done by a qualified person or an authorized service center only.
ADVICE
1. Clean out the parts 34~39 and oil after every 500 operations.
2. Change the parts 35~39 every 2000 operations when pulling 5/16” steel rivets.
3. The part 60 (mandrel bottle) needs to be empty when it is filled with 35 rivets’ residues.
PROBLEM
CAUSE
REMEDY
The different rivets need to have the correct
nosepiece, jaw and jaw pusher installed.
Wrong size rivet.
Please read the operation instructions and check
the rivet size again, see page 3.
Use the adjustable wrench or No. 65 spanner to
open Frame Head (No. 34), then use the 19 mm
Rivet jammed
Some chips were jammed in
spanner to open Jaw Housing (No. 35).
the (35) parts internal.
Use blow gun to clean out chips and then spread oil
on the parts.
Lock back the parts No. 34 & 35, see page 3.
Had some chips stuck on
When you pull the aluminum rivet , it happens
the 33-2 ~ 33-4 parts top.
frequently. Use the steel brush to clear the chips away.
The mandrel was not vacuumed by
Release the trigger halfway.
the Safety Cap (No. 60Z)
The trigger valve had
The Trigger Valve (No. 29) needs to be repaired
No vacuum
malfunctioned.
or replaced.
The O-Ring was damaged.
The O-Ring (No. 58) needs to be replaced.
The nosepiece did not hold the rivet. Press the trigger halfway.
The trigger valve was
The Trigger Valve (No. 29) needs to be repaired
Air leaking.
malfunction.
or replaced.
One of the control valves parts
The damaged O-Rings (Nos. 25, 26 & 27) or
was damaged.
Control Valve (No. 28) need to be repaired.
The Frame Head (38)
Some of the Parts (8) (9) (10)
The damaged part needs to be replaced.
was out of order.
were damaged.
The air supply had loosened.
Re-install and tighten the tube.
Tool run slowly or
One of the control valves parts
The damaged parts (25) , (26) , (27) or (28) need to be
had loss of power.
was damaged.
repaired.
The operating pressure was
Increase the operating pressure to 90 psi.
too low.