background image

DRY2468N_SVG

1

1.  

Earth/Ground Screw

Figure 18

4.  

Use a strain relief and insert end of power cord through power
supply hole.

DRY2469N_SVG

1

1.  

Strain Relief

Figure 19

5.  

Attach power cord earth/ground (green) wire to rear bulkhead
using earth/ground screw removed in Step 3.

4-Wire Connection

DRY2482N_SVG

1

2

3

4

5

6

7

8

1.  

Neutral Terminal

2.  

“L2” Terminal

3.  

Black

4.  

White

5.  

Earth/Ground

6.  

Red

7.  

“L1” Terminal

8.  

Earth/Ground to Neutral Wire

Figure 20

6.  

Use the three screws from the accessories bag to attach the re-
maining power cord wires to the terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.

NOTE: When installing the white wire, loop the free
eyelet end of the earth/ground to neutral wire (re-
moved in Step 3) and attach along with the white
wire to the neutral (center) terminal on the terminal
block.

7.  

Using a screwdriver, tighten all screws firmly.

IMPORTANT: Failure to tighten these screws firmly
may result in wire failure at the terminal block.

8.  

Secure the strain relief to the power cord, or wires, where they
enter the dryer cabinet.

9.  

Check the continuity of the earth/ground connection before
plugging the cord into an outlet. Use an acceptable indicating
device connected to the center earth/ground pin of the plug
and the green screw on the back of the cabinet.

10.  

Reinstall access cover and screw.

Installation

  18

©

 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT

  Part No. 804671R2

Summary of Contents for ATGE9AGPWH

Page 1: ...uctions for Stacked Washer Dryers Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www speedqueen com Part No 804671R2 September 2014 ...

Page 2: ......

Page 3: ...e any phone in your building Clear the room building or area of all occu pants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup plier W052 IMPORTANT Purchaser must consult the local gas sup...

Page 4: ...ARNING To reduce the risk of severe injury or death follow all installation instructions Save these instructions W894 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W053 This product uses FreeRTOS V7 2 0 www freertos org The following information applies to the state of Massachusetts USA This appliance can o...

Page 5: ... Ground Information 15 Connecting Power Cord with Three Wire Plug 15 Connecting Power Cord with Four Wire Plug 17 Connect Dryer Exhaust System 19 Exhaust Direction 20 Exhaust System 20 Position and Level the Unit 20 Wipe Out Inside of Washer and Dryer Drums 22 Plug In the Washer and Dryer 22 Electric Dryer 22 Gas Dryer 22 Washer 24 Check Installation 25 Check Heat Source 25 Electric Dryers 26 Gas ...

Page 6: ... D 8 375 in 213 mm E 24 in 610 mm F 8 in 203 mm G 15 4 in 391 mm H 36 9 in 938 mm I 14 5 in 368 mm J 32 in 813 mm K 26 875 in 683 mm L 46 62 in 1184 mm M 78 17 in 1986 mm N 2 04 in 52 mm O 27 73 in 704 mm P 1 5 in 38 mm Q 13 1 in 333 mm Dimensions Part No 804671R2 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 6 ...

Page 7: ...in 1678 mm B 56 97 in 1447 mm C 23 5 in 597 mm D 8 375 in 213 mm E 24 in 610 mm F 8 in 203 mm G 15 4 in 391 mm H 2 3 in 59 mm I 36 9 in 938 mm J 14 5 in 368 mm K 44 87 in 1140 mm L 32 in 813 mm M 26 875 in 683 mm N 46 62 in 1184 mm O 78 17 in 1986 mm P 2 04 in 52 mm Q 27 73 in 704 mm R 1 5 in 38 mm Dimensions Part No 804671R2 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 7 ...

Page 8: ...S 13 1 in 333 mm With leveling legs turned into base NOTE Exhaust openings are 4 inch 102 mm metal ducting Dimensions 8 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Part No 804671R2 ...

Page 9: ...o fill hoses with washers and filter screens Four rubber feet Beaded strap Removing Dryer Use the following steps if the installation requires removal of the dryer Two people are required to perform this task 1 Remove dryer front access panel 2 Remove two screws holding control panel to control cabinet 3 Remove two 7 16 inch screws and washers attaching dryer to washer 4 Tip dryer back and disconn...

Page 10: ...um span 16 feet 2x10 joists 16 inches on center 1 inch sub floor The stack washer dryer must be installed on a smooth non slip surface Un level tile and extremely slippery surfaces should be avoided Do not install the washer on carpeting soft tile or other weakly supported structures Failure to meet the minimum floor load and surface requirements or installing the products on above ground floors c...

Page 11: ...nd the pressure of both the hot and cold water supply lines WARNING To prevent personal injury avoid contact with inlet water temperatures higher than 125 Fahrenheit 51 Celsius and hot surfaces W748 Maximum flow rate for all water temperatures is 2 5 gallons per minute 9 46 liters per minute 15 Water pressure must be a minimum of 20 to a maximum of 120 pounds per square inch minimum of 138 to a ma...

Page 12: ... be checked on a monthly basis for any visible signs of deterioration Any hose showing the signs of deteriora tion listed above should be replaced immediately All hoses should be replaced every five years Risers Risers or air cushions may have to be installed if the pipes knock or pound when flow of water stops The risers are more ef ficient when installed as close as possible to the water supply ...

Page 13: ...cured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 9 NOTE End of drain hose must not be below 24 in 610 mm H023i_SVG 1 3 2 1 Drain Hose 2 Beaded Strap tape if necessary 3 Fill Hoses Figure 9 Laundry Tub Installation For this type of installation the drain hose MUST be secured to the stationary tub to prevent hose from disloding during use Re fer to Figure 10...

Page 14: ... 3000 feet 915 m the nat ural gas valve spud orifice size must be reduced to ensure com plete combustion Refer to Table 1 Natural Gas Altitude Adjustments Altitude Orifice Size Part No feet m No inches mm 3000 915 43 0 0890 2 26 503778 6000 1830 44 0 0860 2 18 58719 8000 2440 45 0 0820 2 08 503779 9000 2740 46 0 0810 2 06 503780 Natural Gas Altitude Adjustments Altitude Orifice Size Part No feet m...

Page 15: ...ly connected to protective earth ground metal permanent wiring system or an equipment earth ground conductor must be run with the circuit conductors and connected to the equipment earth ground terminal or lead on the dryer The dryer has its own terminal block that must be connected to a separate branch 60 Hertz single phase circuit AC alternating current circuit fused at 30 Amperes the circuit mus...

Page 16: ...ice Entrance Switch Box Refer to NOTE above 8 30 Ampere Fuses or Circuit Breaker 9 Neutral Wire 10 Metallic or Non Metallic Sheathed Cable Copper Wire Only 11 Power Cord Not supplied with dryer 12 Neutral 13 Terminal Block in Dryer 14 Intermediate Shut Off Box may or may not be fused 15 Direct Connection 16 Power Cord Connection Figure 12 1 Disconnect power to dryer 2 Remove access cover from rear...

Page 17: ...table indicating device connected to the center earth ground pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord with Four Wire Plug NOTE Four wire cord is required for new branch cir cuit installations mobile homes or where codes do not permit grounding through neutral DRY2016N_SVG 7 7 7 7 6 3 2 1 4 5 1 Typical Four Wire Receptac...

Page 18: ...wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along with the white wire to the neutral center terminal on the terminal block 7 Using a screwdriver tighten all screws firmly IMPORTANT Failure to tighten these screws firmly may result in wire failure at the terminal block 8 Secure the strain rel...

Page 19: ...correct Figure 21 DO NOT use plastic thin foil or type B ducting Rigid metal duct is recommended Locate dryer so exhaust duct is as short as possible Be certain old exhaust ducts are cleaned before installing your new dryer Use 4 inch 102 mm diameter rigid or flexible metal duct The male end of each section of duct must point away from the dryer Use as few elbows as possible Use of duct tape or po...

Page 20: ...ctional Exhaust Kit 528P3 available as optional equipment at extra cost Exhaust System For best drying results recommended maximum length of ex haust system is shown in Table 4 To prevent backdraft when dryer is not in operation outer end of exhaust pipe must have a weather hood with hinged dampers ob tain locally NOTE Weather hood should be installed at least 12 in ches 305 mm above the ground La...

Page 21: ...n the transportation of the unit may cause damage to the dispenser or doors 2 Place unit in position on a solid sturdy and level floor Instal ling the unit on any type of carpeting soft tile or other weakly supported structures is not recommended 3 Place a level on the raised portion of cabinet top and check if the unit is level from side to side and front to back 4 If unit is not level tilt unit ...

Page 22: ...4 Plug In the Washer and Dryer Electric Dryer Connect the dryer to an electrical power source Refer to Connect Electrical Plug section for information on connecting power cord Connect to 30 Amp Circuit D275I_SVG2 Figure 25 Gas Dryer Dryer requires 120 Volt 60 Hertz electrical supply and comes equipped with a 3 prong earth ground plug Refer to serial plate for specific electrical requirements NOTE ...

Page 23: ...round plug on the power cord should be plugged directly into a polarized three slot effective earth ground receptacle rated 120 Volts AC alternating current 15 Amps Re fer to Figure 26 to determine correct polarity of the wall recepta cle Plug Cord Into Separately Fused 15 Amp Circuit DRY2022N_SVG 7 6 8 5 4 3 2 1 1 L1 2 Earth Ground 3 Neutral 4 Round Earth Ground Plug 5 Neutral Side 6 0 V A C 7 12...

Page 24: ... serial plate for specific electrical requirements NOTE The wiring diagram is located behind the con trol panel inside the control cabinet WARNING To reduce the risk of fire electric shock serious in jury or death all wiring and protective earth ground connections MUST conform with the latest edition of the National Electrical Code ANSI NFPA No 70 and such local regulations as might apply It is th...

Page 25: ...d W893 DO NOT modify the plug provided with the unit if it will not fit the outlet have a proper outlet installed by a qualified electrician If the laundry room s electrical supply does not meet the above specifications and or if you are not sure the laundry room has an effective earth ground have a qualified electri cian or your local electrical utility company check it and cor rect any problems ...

Page 26: ...ive minutes observe burner flame through lower front panel 4 Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roar ing very blue flame indicates too much air Adjust the air shutter as follows a Loosen the air shutter lockscrew b Turn the air shutter to the left to get a luminous yellow tipped flame then turn it back slowly to the r...

Page 27: ......

Page 28: ...t Inside of Washer and Dryer Drums SWD1030N_SVG CHECK CHECK 4 Connect Drain Hose to Drain Receptacle SWD1010N_SVG1 10 Plug In Washer and Dryer DRY2669N_SVG CHECK CHECK 5 GAS ONLY Connect Gas Supply Pipe Check for Gas Leaks D233I_SVG1 11 Recheck Steps CHECK CHECK 6 ELECTRIC ONLY Con nect Electrical Cord D679I_SVG1 12 Start and Run Dryer in Heat Setting to Verify Dryer is Heating CHECK CHECK Refer t...

Reviews: